2021MaterialsOpen access

Microstructure and Properties of SUS304 Stainless Steel Joints Brazed with Electrodeposited Ni-Cr-P Alloy Coatings

Shubin Liu, Ikuo Shohji, Tatsuya Kobayashi, Katsuharu Osanai, Tetsuya Ando, Junichiro Hirohashi, Tsunehito Wake, Katsufumi Inoue, Hiroki Yamamoto

Open full text 7 citations

Abstract

In this study, an amorphous Ni-13.4Cr-11.6P (mass%) alloy coating with a thickness of 30 μm was deposited on the surface of SUS304 stainless steel as a brazing filler metal to conduct brazing. The differential thermal analysis measurements indicate that the electrodeposited Ni-13.4Cr-11.6P alloy has a melting point of approximately 892 °C, which is almost consistent with that of the commercial BNi-7 filler metal. The microstructure, shear strength, and fracture mode of the brazed joint were investigated using an electron probe X-ray microanalyzer, a scanning electron microscope, an optical microscope, and a universal testing machine. The results showed that the brazed filler metal is filled between the SUS304 stainless steel plates without any flaws in the brazed seam. The P-containing phases, i.e., the Cr-P rich phase and the (Ni,Fe)3P phase, were formed in the brazed seam. The shear strength of the brazed joint obtained in this study is 59.0 MPa. The fracture occurs in the brazed filler zone, where the brittle P-containing phases are present. Galvanic current measurement results showed that the brazed Ni-13.4Cr-11.6P alloy coating has a better corrosion resistance than that of the brazed Ni-11P alloy coating, which can be attributed to the formation of a large amount of Ni-Fe solid solution and Cr-P rich phase in the top layer of the brazed Ni-13.4Cr-11.6P alloy coating.

Open-access reader

About this research paper

What this paper is about

In this study, an amorphous Ni-13.4Cr-11.6P (mass%) alloy coating with a thickness of 30 μm was deposited on the surface of SUS304 stainless steel as a brazing filler metal to conduct brazing. The differential thermal analysis measurements indicate that the electrodeposited Ni-13.4Cr-11.6P alloy has a melting point of approximately 892 °C, which is almost consistent with that of the commercial BNi-7 filler metal. The microstructure, shear strength, and fracture mode of the brazed joint were investigated using an electron probe X-ray microanalyzer, a scanning electron microscope, an optical microscope, and a universal testing machine. The results showed that the brazed filler metal is filled between the SUS304 stainless steel plates without any flaws in the brazed seam. The P-containing phases, i.e., the Cr-P rich phase and the (Ni,Fe)3P phase, were formed in the brazed seam. The shear strength of the brazed joint obtained in this study is 59.0 MPa. The fracture occurs in the brazed filler zone, where the brittle P-containing phases are present. Galvanic current measurement results showed that the brazed Ni-13.4Cr-11.6P alloy coating has a better corrosion resistance than that of the brazed Ni-11P alloy coating, which can be attributed to the formation of a large amount of Ni-Fe solid solution and Cr-P rich phase in the top layer of the brazed Ni-13.4Cr-11.6P alloy coating.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, an amorphous Ni-13.4Cr-11.6P (mass%) alloy coating with a thickness of 30 μm was deposited on the surface of SUS304 stainless steel as a brazing filler metal to conduct brazing. The differential thermal analysis measurements indicate that the electrodeposited Ni-13.4Cr-11.6P alloy has a melting point of approximately 892 °C, which is almost consistent with that of the commercial BNi-7 filler metal. The microstructure, shear strength, and fracture mode of the brazed joint were investigated using an electron probe X-ray microanalyzer, a scanning electron microscope, an optical microscope, and a universal testing machine. The results showed that the brazed filler metal is filled between the SUS304 stainless steel plates without any flaws in the brazed seam. The P-containing phases, i.e., the Cr-P rich phase and the (Ni,Fe)3P phase, were formed in the brazed seam. The shear strength of the brazed joint obtained in this study is 59.0 MPa. The fracture occurs in the brazed filler zone, where the brittle P-containing phases are present. Galvanic current measurement results showed that the brazed Ni-13.4Cr-11.6P alloy coating has a better corrosion resistance than that of the brazed Ni-11P alloy coating, which can be attributed to the formation of a large amount of Ni-Fe solid solution and Cr-P rich phase in the top layer of the brazed Ni-13.4Cr-11.6P alloy coating.

Key concepts: Brazing, Materials science, Microstructure, Alloy, Metallurgy, Filler metal, Coating, Scanning electron microscope

Related papers

Back to paper searchBrowse research topicsOriginal source
Microstructure and Properties of SUS304 Stainless Steel Joints Brazed with Electrodeposited Ni-Cr-P Alloy Coatings — Research Paper | ScholarLens