2021EnergiesOpen access

Invert Drilling Fluids with High Internal Phase Content

S. Błaż, Grzegorz Zima, B. Jasiński, Marcin Kremieniewski

Open full text 7 citations

Abstract

One of the most important tasks when drilling a borehole is to select the appropriate type of drilling fluid and adjust its properties to the borehole’s conditions. This ensures the safe and effective exploitation of the borehole. Many types of drilling fluids are used to drill holes for crude oil and natural gas. Most often, mainly due to cost and environmental constraints, water-based muds are used. On the other hand, invert drilling fluids are used for drilling holes in difficult geological conditions. The ratio of the oil phase to the water phase in invert drilling fluids the most common ratio being from 70/30 to 90/10. One of the disadvantages of invert drilling fluids is their cost (due to the oil content) and environmental problems related to waste and the management of oily cuttings. This article presents tests of invert drilling fluids with Oil-Water Ratio (OWR) 50/50 to 20/80 which can be used for drilling HPHT wells. The invert drilling fluids properties were examined and their resistance to temperature and pressure was assessed. Their effect on the permeability of reservoir rocks was also determined. The developed invert drilling fluids are characterized by high electrical stability ES above 300 V, and stable rheological parameters and low filtration. Due to the reduced content of the oil, the developed drilling fluid system is more economical and has limited toxicity.

Open-access reader

About this research paper

What this paper is about

One of the most important tasks when drilling a borehole is to select the appropriate type of drilling fluid and adjust its properties to the borehole’s conditions. This ensures the safe and effective exploitation of the borehole. Many types of drilling fluids are used to drill holes for crude oil and natural gas. Most often, mainly due to cost and environmental constraints, water-based muds are used. On the other hand, invert drilling fluids are used for drilling holes in difficult geological conditions. The ratio of the oil phase to the water phase in invert drilling fluids the most common ratio being from 70/30 to 90/10. One of the disadvantages of invert drilling fluids is their cost (due to the oil content) and environmental problems related to waste and the management of oily cuttings. This article presents tests of invert drilling fluids with Oil-Water Ratio (OWR) 50/50 to 20/80 which can be used for drilling HPHT wells. The invert drilling fluids properties were examined and their resistance to temperature and pressure was assessed. Their effect on the permeability of reservoir rocks was also determined. The developed invert drilling fluids are characterized by high electrical stability ES above 300 V, and stable rheological parameters and low filtration. Due to the reduced content of the oil, the developed drilling fluid system is more economical and has limited toxicity.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

One of the most important tasks when drilling a borehole is to select the appropriate type of drilling fluid and adjust its properties to the borehole’s conditions. This ensures the safe and effective exploitation of the borehole. Many types of drilling fluids are used to drill holes for crude oil and natural gas. Most often, mainly due to cost and environmental constraints, water-based muds are used. On the other hand, invert drilling fluids are used for drilling holes in difficult geological conditions. The ratio of the oil phase to the water phase in invert drilling fluids the most common ratio being from 70/30 to 90/10. One of the disadvantages of invert drilling fluids is their cost (due to the oil content) and environmental problems related to waste and the management of oily cuttings. This article presents tests of invert drilling fluids with Oil-Water Ratio (OWR) 50/50 to 20/80 which can be used for drilling HPHT wells. The invert drilling fluids properties were examined and their resistance to temperature and pressure was assessed. Their effect on the permeability of reservoir rocks was also determined. The developed invert drilling fluids are characterized by high electrical stability ES above 300 V, and stable rheological parameters and low filtration. Due to the reduced content of the oil, the developed drilling fluid system is more economical and has limited toxicity.

Key concepts: Drilling fluid, Borehole, Petroleum engineering, Drilling, Drill cuttings, Rheology, Mud logging, Geology

Related papers

Back to paper searchBrowse research topicsOriginal source
Invert Drilling Fluids with High Internal Phase Content — Research Paper | ScholarLens