2021•Circulation JournalOpen access

Complementary Assessment by Hybrid Intravascular Ultrasound-Optical Coherence Tomography Catheter After Implantation of a New-Generation Drug-Eluting Stent

Tatsunori Takahashi, Azeem Latib, Yuhei Kobayashi

Open full text 2 citations

Abstract

This record does not include an abstract. Use the full-text link above if available.

Open-access reader

About this research paper

What this paper is about

An abstract is not available in the OpenAlex record for this paper.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Key concepts: Intravascular ultrasound, Optical coherence tomography, Drug-eluting stent, Medicine, Stent, Radiology, Catheter, Biomedical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Complementary Assessment by Hybrid Intravascular Ultrasound-Optical Coherence Tomography Catheter After Implantation of a New-Generation Drug-Eluting Stent — Research Paper | ScholarLens