2021•Scientific ReportsOpen access

Association of peripheral anterior synechiae with anterior segment parameters in eyes with primary angle closure glaucoma

Yunhua Loo, Tin A. Tun, Eranga N. Vithana, Shamira Perera, Rahat Husain, Tina Tzee Ling Wong, Tin Aung, Monisha Esther Nongpiur

Open full text 14 citations

Abstract

To investigate the association of peripheral anterior synechiae (PAS) with intraocular pressure (IOP) and anterior-segment parameters in subjects with primary angle-closure glaucoma (PACG). A total of 267 subjects with PACG were recruited and underwent gonioscopy and anterior-segment optical coherence tomography (ASOCT). Customized software was used to measure ASOCT parameters, including angle opening distance (AOD750) and trabecular-iris-space-area (TISA750) at 750 µm from the scleral spur, anterior chamber depth, width, area and volume (ACD, ACW, ACA, ACV), iris thickness (IT750), iris area (IAREA), and lens vault (LV). Presenting IOP was defined as the first IOP reading before the initiation of IOP-lowering treatment. The mean age of the 267 subjects was 67.0 ± 8.9 years, 140 (52.4%) were male, and 246 (92.1%) were of Chinese ethnicity. PAS was present in 122 (45.7%) subjects, and was most frequently found in the superior quadrant (79.5%). Subjects with PAS had greater presenting IOP (28.7 ± 12.9 vs 22.4 ± 9.7 mmHg, p < 0.001), narrower AOD750 (p < 0.001), smaller TISA750 (p < 0.001), ACD (p = 0.04), ACA (p = 0.02), ACV (p = 0.01) and larger LV (p = 0.01) compared to PACG eyes without PAS. No significant differences were noted for iris parameters. A multivariate logistic regression analysis showed that higher presenting IOP (β = 0.20, p < 0.001), worse visual field mean deviation (β = - 0.20, p = 0.01) and narrower AOD750 (β = - 0.25, p = 0.03) were the only parameters that significantly correlated with the extent of PAS in clock hours. Almost one-half of the subjects with PACG demonstrated PAS; these eyes were associated with higher presenting IOP, smaller anterior segment dimensions and more severe disease.

Open-access reader

About this research paper

What this paper is about

To investigate the association of peripheral anterior synechiae (PAS) with intraocular pressure (IOP) and anterior-segment parameters in subjects with primary angle-closure glaucoma (PACG). A total of 267 subjects with PACG were recruited and underwent gonioscopy and anterior-segment optical coherence tomography (ASOCT). Customized software was used to measure ASOCT parameters, including angle opening distance (AOD750) and trabecular-iris-space-area (TISA750) at 750 µm from the scleral spur, anterior chamber depth, width, area and volume (ACD, ACW, ACA, ACV), iris thickness (IT750), iris area (IAREA), and lens vault (LV). Presenting IOP was defined as the first IOP reading before the initiation of IOP-lowering treatment. The mean age of the 267 subjects was 67.0 ± 8.9 years, 140 (52.4%) were male, and 246 (92.1%) were of Chinese ethnicity. PAS was present in 122 (45.7%) subjects, and was most frequently found in the superior quadrant (79.5%). Subjects with PAS had greater presenting IOP (28.7 ± 12.9 vs 22.4 ± 9.7 mmHg, p < 0.001), narrower AOD750 (p < 0.001), smaller TISA750 (p < 0.001), ACD (p = 0.04), ACA (p = 0.02), ACV (p = 0.01) and larger LV (p = 0.01) compared to PACG eyes without PAS. No significant differences were noted for iris parameters. A multivariate logistic regression analysis showed that higher presenting IOP (β = 0.20, p < 0.001), worse visual field mean deviation (β = - 0.20, p = 0.01) and narrower AOD750 (β = - 0.25, p = 0.03) were the only parameters that significantly correlated with the extent of PAS in clock hours. Almost one-half of the subjects with PACG demonstrated PAS; these eyes were associated with higher presenting IOP, smaller anterior segment dimensions and more severe disease.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To investigate the association of peripheral anterior synechiae (PAS) with intraocular pressure (IOP) and anterior-segment parameters in subjects with primary angle-closure glaucoma (PACG). A total of 267 subjects with PACG were recruited and underwent gonioscopy and anterior-segment optical coherence tomography (ASOCT). Customized software was used to measure ASOCT parameters, including angle opening distance (AOD750) and trabecular-iris-space-area (TISA750) at 750 µm from the scleral spur, anterior chamber depth, width, area and volume (ACD, ACW, ACA, ACV), iris thickness (IT750), iris area (IAREA), and lens vault (LV). Presenting IOP was defined as the first IOP reading before the initiation of IOP-lowering treatment. The mean age of the 267 subjects was 67.0 ± 8.9 years, 140 (52.4%) were male, and 246 (92.1%) were of Chinese ethnicity. PAS was present in 122 (45.7%) subjects, and was most frequently found in the superior quadrant (79.5%). Subjects with PAS had greater presenting IOP (28.7 ± 12.9 vs 22.4 ± 9.7 mmHg, p < 0.001), narrower AOD750 (p < 0.001), smaller TISA750 (p < 0.001), ACD (p = 0.04), ACA (p = 0.02), ACV (p = 0.01) and larger LV (p = 0.01) compared to PACG eyes without PAS. No significant differences were noted for iris parameters. A multivariate logistic regression analysis showed that higher presenting IOP (β = 0.20, p < 0.001), worse visual field mean deviation (β = - 0.20, p = 0.01) and narrower AOD750 (β = - 0.25, p = 0.03) were the only parameters that significantly correlated with the extent of PAS in clock hours. Almost one-half of the subjects with PACG demonstrated PAS; these eyes were associated with higher presenting IOP, smaller anterior segment dimensions and more severe disease.

Key concepts: Gonioscopy, Medicine, Ophthalmology, Glaucoma, Intraocular pressure, Anterior chamber angle, IRIS (biosensor), Computer security

Related papers

Back to paper searchBrowse research topicsOriginal source
Association of peripheral anterior synechiae with anterior segment parameters in eyes with primary angle closure glaucoma — Research Paper | ScholarLens