Design Analysis of 110kV Double Circuit Narrow-Base Steel Pipe Tower
Ye Xin, Yinhe Lin, Jingfeng Guo, Xiaoxu Fu, Ming Yu Xie
Abstract
Open-access reader
Ye Xin, Yinhe Lin, Jingfeng Guo, Xiaoxu Fu, Ming Yu Xie
Abstract
Open-access reader
Secondary bending moment and geometric nonlinearity should be taken into account in pipe tower design. Taking the 110kV double-circuit narrow-base steel pipe tower as an example, the 110 kV double-circuit narrow-base steel pipe tower is compared and analyzed through the tower structure design software and the general finite element software ANSYS. The analysis results show that the narrow-base steel tube tower should adopt a rigid-truss structure model, and the influence of the secondary bending moment of the main material and the geometric nonlinearity should be considered. The secondary bending moment effect accounts for about 10-20% of the strength stress of the steel pipe main material. Through comparative analysis, a number of design points are summarized, which provides a certain practical guiding significance for the design and application of the double-circuit narrow-base steel pipe tower.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Secondary bending moment and geometric nonlinearity should be taken into account in pipe tower design. Taking the 110kV double-circuit narrow-base steel pipe tower as an example, the 110 kV double-circuit narrow-base steel pipe tower is compared and analyzed through the tower structure design software and the general finite element software ANSYS. The analysis results show that the narrow-base steel tube tower should adopt a rigid-truss structure model, and the influence of the secondary bending moment of the main material and the geometric nonlinearity should be considered. The secondary bending moment effect accounts for about 10-20% of the strength stress of the steel pipe main material. Through comparative analysis, a number of design points are summarized, which provides a certain practical guiding significance for the design and application of the double-circuit narrow-base steel pipe tower.
Key concepts: Structural engineering, Tower, Truss, Bending moment, Base (topology), Engineering, Finite element method, Moment (physics)