2021Veterinary OphthalmologyRequires access

Efficacy of biodegradable collagen matrix (Ologen®CM) in augmenting the success rate of Ahmed glaucoma valve implantation in canine glaucoma

W.-T. Hong, Joon‐Young Kim, Sukjun Lee, Soon‐wuk Jeong

Open publisher page 2 citations

Abstract

OBJECTIVE: To prospectively assess the efficacy of a biodegradable collagen matrix (ologen) in dogs with uncontrolled glaucoma receiving an Ahmed glaucoma valve (AGV) implant. ANIMAL STUDIED: Five client-owned dogs with glaucoma (five eyes). PROCEDURES: Five eyes treated for uncontrolled glaucoma underwent AGV implantation with ologen. Ologen was placed on the AGV plate and tube with a scleral flap. Complete ophthalmological examinations were performed preoperatively and at 1 and 3 days, 1 and 2 weeks, and 1, 2, 3, and 6 months postoperatively. Surgical outcomes were assessed based on the intraocular pressure (IOP), vision, frequency of anti-glaucoma eye drops, and bleb morphology; complications, if any, were recorded. The number of dogs with an IOP <20 mmHg with or without topical medications were tabulated and compared to those with an IOP ≥20 mmHg or those requiring surgery to maintain the IOP at <20 mmHg. RESULTS: The IOP significantly decreased from 47.00 ± 5.09 mmHg preoperatively to 17.00 ± 0.71 mmHg 6 months postoperatively (p = .008). IOP was controlled (<20 mmHg) in 5/5 dogs at 6 months postoperatively. Brief periods of elevated IOP (IOP ≥ 20 mmHg, IOP spike) occurred in one eye (case 5) at 1 month (35 mmHg) and 2 months (33 mmHg) postoperatively. The anti-glaucoma eye drop frequency decreased from 3.2 ± 0.44 preoperatively to 1.6 ± 0.90 at 6 months postoperatively (p = .007). CONCLUSIONS: To our knowledge, this is the first study to assess the potential safety of AGV implantation with ologen for canine glaucoma. This method effectively controlled the IOP, without any adverse effects.

About this research paper

What this paper is about

OBJECTIVE: To prospectively assess the efficacy of a biodegradable collagen matrix (ologen) in dogs with uncontrolled glaucoma receiving an Ahmed glaucoma valve (AGV) implant. ANIMAL STUDIED: Five client-owned dogs with glaucoma (five eyes). PROCEDURES: Five eyes treated for uncontrolled glaucoma underwent AGV implantation with ologen. Ologen was placed on the AGV plate and tube with a scleral flap. Complete ophthalmological examinations were performed preoperatively and at 1 and 3 days, 1 and 2 weeks, and 1, 2, 3, and 6 months postoperatively. Surgical outcomes were assessed based on the intraocular pressure (IOP), vision, frequency of anti-glaucoma eye drops, and bleb morphology; complications, if any, were recorded. The number of dogs with an IOP <20 mmHg with or without topical medications were tabulated and compared to those with an IOP ≥20 mmHg or those requiring surgery to maintain the IOP at <20 mmHg. RESULTS: The IOP significantly decreased from 47.00 ± 5.09 mmHg preoperatively to 17.00 ± 0.71 mmHg 6 months postoperatively (p = .008). IOP was controlled (<20 mmHg) in 5/5 dogs at 6 months postoperatively. Brief periods of elevated IOP (IOP ≥ 20 mmHg, IOP spike) occurred in one eye (case 5) at 1 month (35 mmHg) and 2 months (33 mmHg) postoperatively. The anti-glaucoma eye drop frequency decreased from 3.2 ± 0.44 preoperatively to 1.6 ± 0.90 at 6 months postoperatively (p = .007). CONCLUSIONS: To our knowledge, this is the first study to assess the potential safety of AGV implantation with ologen for canine glaucoma. This method effectively controlled the IOP, without any adverse effects.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To prospectively assess the efficacy of a biodegradable collagen matrix (ologen) in dogs with uncontrolled glaucoma receiving an Ahmed glaucoma valve (AGV) implant. ANIMAL STUDIED: Five client-owned dogs with glaucoma (five eyes). PROCEDURES: Five eyes treated for uncontrolled glaucoma underwent AGV implantation with ologen. Ologen was placed on the AGV plate and tube with a scleral flap. Complete ophthalmological examinations were performed preoperatively and at 1 and 3 days, 1 and 2 weeks, and 1, 2, 3, and 6 months postoperatively. Surgical outcomes were assessed based on the intraocular pressure (IOP), vision, frequency of anti-glaucoma eye drops, and bleb morphology; complications, if any, were recorded. The number of dogs with an IOP <20 mmHg with or without topical medications were tabulated and compared to those with an IOP ≥20 mmHg or those requiring surgery to maintain the IOP at <20 mmHg. RESULTS: The IOP significantly decreased from 47.00 ± 5.09 mmHg preoperatively to 17.00 ± 0.71 mmHg 6 months postoperatively (p = .008). IOP was controlled (<20 mmHg) in 5/5 dogs at 6 months postoperatively. Brief periods of elevated IOP (IOP ≥ 20 mmHg, IOP spike) occurred in one eye (case 5) at 1 month (35 mmHg) and 2 months (33 mmHg) postoperatively. The anti-glaucoma eye drop frequency decreased from 3.2 ± 0.44 preoperatively to 1.6 ± 0.90 at 6 months postoperatively (p = .007). CONCLUSIONS: To our knowledge, this is the first study to assess the potential safety of AGV implantation with ologen for canine glaucoma. This method effectively controlled the IOP, without any adverse effects.

Key concepts: Glaucoma valve, Glaucoma, Matrix (chemical analysis), Ophthalmology, Anatomy, Biomedical engineering, Chemistry, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficacy of biodegradable collagen matrix (Ologen®CM) in augmenting the success rate of Ahmed glaucoma valve implantation in canine glaucoma — Research Paper | ScholarLens