2021Reproduction in Domestic AnimalsOpen access

Combined cryopreservation of canine ejaculates collected at a one‐hour interval increases semen doses for artificial insemination without negative effects on post‐thaw sperm characteristics

Dominik Lechner, Jörg Aurich, Sabine Schäfer–Somi, Johannes Herbel, Christine Aurich

Open full text 8 citations

Abstract

A limiting factor in canine artificial insemination (AI) is the low number of insemination doses obtained per ejaculate. In this study, semen was collected from dogs (n = 28) either once and frozen directly after collection or the same dogs were submitted to a dual semen collection with a 1-hr interval and the two ejaculates were combined for cryopreservation. We hypothesized that combining two ejaculates increases semen doses per cryopreservation process without negative effects on semen characteristics. Total sperm count was lower in semen from a single semen collection in comparison with the combination of the first and second ejaculate of a dual semen collection (p < .001). The percentage of motile and membrane-intact spermatozoa determined by computer-assisted sperm analysis (CASA) in raw semen did not differ between single and combined dual ejaculates and was reduced (p < .001) by cryopreservation to the same extent in single (motility 73.7 ± 1.8%, membrane integrity 65.6 ± 2.2%) and combined dual ejaculates (motility 72.7 ± 2.3%, membrane integrity 64.6 ± 2.5%). The percentage of spermatozoa with morphological defects increased after cryopreservation (p < .001) but was similar in single and combined dual ejaculates. The CASA sperm velocity parameters decreased with cryopreservation (p < .001) but did not differ between single and combined dual ejaculates. The number of insemination doses increased from 2.7 ± 0.4 for single to 4.7 ± 0.8 for combined dual ejaculates (p < .01), based on 100 million motile spermatozoa per frozen-thawed semen dose. In conclusion, combining two ejaculates collected at short interval for one cryopreservation process increases the number of AI doses without compromising semen quality.

About this research paper

What this paper is about

A limiting factor in canine artificial insemination (AI) is the low number of insemination doses obtained per ejaculate. In this study, semen was collected from dogs (n = 28) either once and frozen directly after collection or the same dogs were submitted to a dual semen collection with a 1-hr interval and the two ejaculates were combined for cryopreservation. We hypothesized that combining two ejaculates increases semen doses per cryopreservation process without negative effects on semen characteristics. Total sperm count was lower in semen from a single semen collection in comparison with the combination of the first and second ejaculate of a dual semen collection (p < .001). The percentage of motile and membrane-intact spermatozoa determined by computer-assisted sperm analysis (CASA) in raw semen did not differ between single and combined dual ejaculates and was reduced (p < .001) by cryopreservation to the same extent in single (motility 73.7 ± 1.8%, membrane integrity 65.6 ± 2.2%) and combined dual ejaculates (motility 72.7 ± 2.3%, membrane integrity 64.6 ± 2.5%). The percentage of spermatozoa with morphological defects increased after cryopreservation (p < .001) but was similar in single and combined dual ejaculates. The CASA sperm velocity parameters decreased with cryopreservation (p < .001) but did not differ between single and combined dual ejaculates. The number of insemination doses increased from 2.7 ± 0.4 for single to 4.7 ± 0.8 for combined dual ejaculates (p < .01), based on 100 million motile spermatozoa per frozen-thawed semen dose. In conclusion, combining two ejaculates collected at short interval for one cryopreservation process increases the number of AI doses without compromising semen quality.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A limiting factor in canine artificial insemination (AI) is the low number of insemination doses obtained per ejaculate. In this study, semen was collected from dogs (n = 28) either once and frozen directly after collection or the same dogs were submitted to a dual semen collection with a 1-hr interval and the two ejaculates were combined for cryopreservation. We hypothesized that combining two ejaculates increases semen doses per cryopreservation process without negative effects on semen characteristics. Total sperm count was lower in semen from a single semen collection in comparison with the combination of the first and second ejaculate of a dual semen collection (p < .001). The percentage of motile and membrane-intact spermatozoa determined by computer-assisted sperm analysis (CASA) in raw semen did not differ between single and combined dual ejaculates and was reduced (p < .001) by cryopreservation to the same extent in single (motility 73.7 ± 1.8%, membrane integrity 65.6 ± 2.2%) and combined dual ejaculates (motility 72.7 ± 2.3%, membrane integrity 64.6 ± 2.5%). The percentage of spermatozoa with morphological defects increased after cryopreservation (p < .001) but was similar in single and combined dual ejaculates. The CASA sperm velocity parameters decreased with cryopreservation (p < .001) but did not differ between single and combined dual ejaculates. The number of insemination doses increased from 2.7 ± 0.4 for single to 4.7 ± 0.8 for combined dual ejaculates (p < .01), based on 100 million motile spermatozoa per frozen-thawed semen dose. In conclusion, combining two ejaculates collected at short interval for one cryopreservation process increases the number of AI doses without compromising semen quality.

Key concepts: Semen, Cryopreservation, Sperm, Andrology, Insemination, Artificial insemination, Biology, Sperm washing

Related papers

Back to paper searchBrowse research topicsOriginal source
Combined cryopreservation of canine ejaculates collected at a one‐hour interval increases semen doses for artificial insemination without negative effects on post‐thaw sperm characteristics — Research Paper | ScholarLens