Assessment of the Effect of Bone Density on Implant Stability: A Clinical Study
Raghunadh Sreerama, Krishna C Kolluru, Vineela Gottumukkala, Chaitanya Kumar Innampudi, Jagga Rao Konathala, G. Krishnaveni
Abstract
Raghunadh Sreerama, Krishna C Kolluru, Vineela Gottumukkala, Chaitanya Kumar Innampudi, Jagga Rao Konathala, G. Krishnaveni
Abstract
Background: In this study, we determined the effect of bone density on implant stability. Methodology: Two hundred and sixty dental implant sites in 128 patients were assessed for resonance frequency analysis (RFA) following implant insertion, at 6 months and 12 months. The implant stability quotient (ISQ) was determined. Results: The mean ± standard deviation bone density in anterior mandible was 862.8 ± 203.4 Hounsfield units (HU), in posterior mandible was 528.4 ± 115.6 HU, in anterior maxilla was 594.2 ± 95.2 HU, and in posterior maxilla was 438.1 ± 110.2 HU. The mean insertion torque in successful implants was 38.2 ± 7.1 Ncm and in failed implants was 22.4 ± 4.2 Ncm. The mean RFA value in successful implants was 65.4 ± 5.8 and in failed implants was 45.8 ± 4.1 ISQ. A statistically significant ( P < 0.05) difference was obtained. Conclusion: Within the limitation of the study, we observed that successful implants exhibited higher RFA and insertion torque and were higher into failed implants suggesting a correlation of bone quality and implant stability parameters.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background: In this study, we determined the effect of bone density on implant stability. Methodology: Two hundred and sixty dental implant sites in 128 patients were assessed for resonance frequency analysis (RFA) following implant insertion, at 6 months and 12 months. The implant stability quotient (ISQ) was determined. Results: The mean ± standard deviation bone density in anterior mandible was 862.8 ± 203.4 Hounsfield units (HU), in posterior mandible was 528.4 ± 115.6 HU, in anterior maxilla was 594.2 ± 95.2 HU, and in posterior maxilla was 438.1 ± 110.2 HU. The mean insertion torque in successful implants was 38.2 ± 7.1 Ncm and in failed implants was 22.4 ± 4.2 Ncm. The mean RFA value in successful implants was 65.4 ± 5.8 and in failed implants was 45.8 ± 4.1 ISQ. A statistically significant ( P < 0.05) difference was obtained. Conclusion: Within the limitation of the study, we observed that successful implants exhibited higher RFA and insertion torque and were higher into failed implants suggesting a correlation of bone quality and implant stability parameters.
Key concepts: Implant stability quotient, Resonance frequency analysis, Hounsfield scale, Implant, Medicine, Dentistry, Mandible (arthropod mouthpart), Anterior maxilla