2021•Remote SensingOpen access

Climatology of Convective Storms in Estonia from Radar Data and Severe Convective Environments

Tanel Voormansik, Tuule Müürsepp, Piia Post

Open full text 10 citations

Abstract

Data from the C-band weather radar located in central Estonia in conjunction with the latest reanalysis of the European Centre for Medium-Range Weather Forecasts (ECMWF), ERA5, and Nordic Lightning Information System (NORDLIS) lightning location system data are used to investigate the climatology of convective storms for nine summer periods (2010–2019, 2017 excluded). First, an automated 35-dBZ reflectivity threshold-based storm area detection algorithm is used to derive initial individual convective cells from the base level radar reflectivity. Those detected cells are used as a basis combined with convective available potential energy (CAPE) values from ERA5 reanalysis to find thresholds for a severe convective storm in Estonia. A severe convective storm is defined as an area with radar reflectivity at least 51 dBZ and CAPE at least 80 J/kg. Verification of those severe convective storm areas with lightning data reveals a good correlation on various temporal scales from hourly to yearly distributions. The probability of a severe convective storm day in the study area during the summer period is 45%, and the probability of a thunderstorm day is 54%. Jenkinson Collison’ circulation types are calculated from ERA5 reanalysis to find the probability of a severe convective storm depending on the circulation direction and the representativeness of the investigated period by comparing it against 1979–2019. The prevailing airflow direction is from SW and W, whereas the probability of the convective storm to be severe is in the case of SE and S airflow. Finally, the spatial distribution of the severe convective storms shows that the yearly mean number of severe convective days for the 100 km2 grid cell is mostly between 3 and 8 in the distance up to 150 km from radar. Severe convective storms are most frequent in W and SW parts of continental Estonia.

Open-access reader

About this research paper

What this paper is about

Data from the C-band weather radar located in central Estonia in conjunction with the latest reanalysis of the European Centre for Medium-Range Weather Forecasts (ECMWF), ERA5, and Nordic Lightning Information System (NORDLIS) lightning location system data are used to investigate the climatology of convective storms for nine summer periods (2010–2019, 2017 excluded). First, an automated 35-dBZ reflectivity threshold-based storm area detection algorithm is used to derive initial individual convective cells from the base level radar reflectivity. Those detected cells are used as a basis combined with convective available potential energy (CAPE) values from ERA5 reanalysis to find thresholds for a severe convective storm in Estonia. A severe convective storm is defined as an area with radar reflectivity at least 51 dBZ and CAPE at least 80 J/kg. Verification of those severe convective storm areas with lightning data reveals a good correlation on various temporal scales from hourly to yearly distributions. The probability of a severe convective storm day in the study area during the summer period is 45%, and the probability of a thunderstorm day is 54%. Jenkinson Collison’ circulation types are calculated from ERA5 reanalysis to find the probability of a severe convective storm depending on the circulation direction and the representativeness of the investigated period by comparing it against 1979–2019. The prevailing airflow direction is from SW and W, whereas the probability of the convective storm to be severe is in the case of SE and S airflow. Finally, the spatial distribution of the severe convective storms shows that the yearly mean number of severe convective days for the 100 km2 grid cell is mostly between 3 and 8 in the distance up to 150 km from radar. Severe convective storms are most frequent in W and SW parts of continental Estonia.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Data from the C-band weather radar located in central Estonia in conjunction with the latest reanalysis of the European Centre for Medium-Range Weather Forecasts (ECMWF), ERA5, and Nordic Lightning Information System (NORDLIS) lightning location system data are used to investigate the climatology of convective storms for nine summer periods (2010–2019, 2017 excluded). First, an automated 35-dBZ reflectivity threshold-based storm area detection algorithm is used to derive initial individual convective cells from the base level radar reflectivity. Those detected cells are used as a basis combined with convective available potential energy (CAPE) values from ERA5 reanalysis to find thresholds for a severe convective storm in Estonia. A severe convective storm is defined as an area with radar reflectivity at least 51 dBZ and CAPE at least 80 J/kg. Verification of those severe convective storm areas with lightning data reveals a good correlation on various temporal scales from hourly to yearly distributions. The probability of a severe convective storm day in the study area during the summer period is 45%, and the probability of a thunderstorm day is 54%. Jenkinson Collison’ circulation types are calculated from ERA5 reanalysis to find the probability of a severe convective storm depending on the circulation direction and the representativeness of the investigated period by comparing it against 1979–2019. The prevailing airflow direction is from SW and W, whereas the probability of the convective storm to be severe is in the case of SE and S airflow. Finally, the spatial distribution of the severe convective storms shows that the yearly mean number of severe convective days for the 100 km2 grid cell is mostly between 3 and 8 in the distance up to 150 km from radar. Severe convective storms are most frequent in W and SW parts of continental Estonia.

Key concepts: Convective available potential energy, Thunderstorm, Convective storm detection, Storm, Severe weather, Meteorology, Climatology, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Climatology of Convective Storms in Estonia from Radar Data and Severe Convective Environments — Research Paper | ScholarLens