Applications of a novel detector for pencil beam scanning proton therapy beam quality assurance
Peiying Yang, Yang-Wei Hsieh, Chen-Lin Kang, Chin-Dar Tseng, Chih‐Hsueh Lin, Chin‐Shiuh Shieh, Pei‐Ju Chao, Tsair-Fwu Lee
Abstract
Peiying Yang, Yang-Wei Hsieh, Chen-Lin Kang, Chin-Dar Tseng, Chih‐Hsueh Lin, Chin‐Shiuh Shieh, Pei‐Ju Chao, Tsair-Fwu Lee
Abstract
This study utilized a new type of detector, the CROSS II (Liverage Biomedical Inc., Taiwan), to perform a beam quality assurance (QA) procedure on a Sumitomo (Sumitomo Heavy Industries, Inc., Japan) pencil beam linear scanning proton therapy machine. The Cross II can monitor proton Pristine Bragg peak range, beam width, beam size, beam position, and scanning speed. All the data presented here were collected during a time span of over one year. The accuracy of the QA program could be verified if all the QA items were tested stably and within the programmed tolerances. Our results showed that the proton range remained within the [Formula: see text] mm tolerance, with the majority of measurements within [Formula: see text] mm, [Formula: see text] mm for spot size, 1.5 mm for spot position, and [Formula: see text]% for scanning speed. We found that the CROSS II detector is in high precise and steady state with highly efficient. Our proton therapy system was also proven to be in an accurate and reliable condition according to our QA results.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study utilized a new type of detector, the CROSS II (Liverage Biomedical Inc., Taiwan), to perform a beam quality assurance (QA) procedure on a Sumitomo (Sumitomo Heavy Industries, Inc., Japan) pencil beam linear scanning proton therapy machine. The Cross II can monitor proton Pristine Bragg peak range, beam width, beam size, beam position, and scanning speed. All the data presented here were collected during a time span of over one year. The accuracy of the QA program could be verified if all the QA items were tested stably and within the programmed tolerances. Our results showed that the proton range remained within the [Formula: see text] mm tolerance, with the majority of measurements within [Formula: see text] mm, [Formula: see text] mm for spot size, 1.5 mm for spot position, and [Formula: see text]% for scanning speed. We found that the CROSS II detector is in high precise and steady state with highly efficient. Our proton therapy system was also proven to be in an accurate and reliable condition according to our QA results.
Key concepts: Pencil-beam scanning, Proton therapy, Bragg peak, Quality assurance, Beam (structure), Detector, Proton, Pencil (optics)