[Detecting of obstructive sleep apnea hypopnea syndrome using a multi-parameter pressure sensitive sleep monitor].

S X Zhang, Zhiyuan Yao, Shuai Luan, L Wang, Yan Xu

Open full text 1 citations

Abstract

OBJECTIVE: To evaluate the efficacy of an electro-mechanical film-based(EMFi) multi-parameter pressure sensitive sleep monitor(MPSSM)on clinical diagnosis and research significance of obstructive sleep apnea hypopnea syndrome(OSAHS). METHODS: Retrospective analysis was made of 58 test subjects at Peking University Third Hospital with suspected OSAHS who were simultaneously monitored by MPSSM and polysomnography(PSG). The PSG test results were used as the gold standard in evaluating the sensitivity and specificity of OSAHS diagnosis of MPSSM. The test result consistency of sleep apnea and hypopnea index(AHI)and total apnea time of the two methods was evaluated. Real-time waveform comparison of sleep respiratory events of a randomly selected patient diagnosed with OSAHS was performed. RESULTS: < 0.001). Bland-Altman plot showed that the consistency between the test results of the two methods was very high. CONCLUSION: As a portable, non-contact, fully automatic monitoring device, MPSSM is reliable in the screening of OSAHS compared with PSG. It is suitable to be promoted and applied in primary medical institutions, nursing homes and domestic usage. However, further research is required in improving the analysis of different sleep phase and the differentiation of central sleep apnea syndrome respiratory events in order to effectively assist medical personnel in making an accurate sleep apnea diagnosis.

About this research paper

What this paper is about

OBJECTIVE: To evaluate the efficacy of an electro-mechanical film-based(EMFi) multi-parameter pressure sensitive sleep monitor(MPSSM)on clinical diagnosis and research significance of obstructive sleep apnea hypopnea syndrome(OSAHS). METHODS: Retrospective analysis was made of 58 test subjects at Peking University Third Hospital with suspected OSAHS who were simultaneously monitored by MPSSM and polysomnography(PSG). The PSG test results were used as the gold standard in evaluating the sensitivity and specificity of OSAHS diagnosis of MPSSM. The test result consistency of sleep apnea and hypopnea index(AHI)and total apnea time of the two methods was evaluated. Real-time waveform comparison of sleep respiratory events of a randomly selected patient diagnosed with OSAHS was performed. RESULTS: < 0.001). Bland-Altman plot showed that the consistency between the test results of the two methods was very high. CONCLUSION: As a portable, non-contact, fully automatic monitoring device, MPSSM is reliable in the screening of OSAHS compared with PSG. It is suitable to be promoted and applied in primary medical institutions, nursing homes and domestic usage. However, further research is required in improving the analysis of different sleep phase and the differentiation of central sleep apnea syndrome respiratory events in order to effectively assist medical personnel in making an accurate sleep apnea diagnosis.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To evaluate the efficacy of an electro-mechanical film-based(EMFi) multi-parameter pressure sensitive sleep monitor(MPSSM)on clinical diagnosis and research significance of obstructive sleep apnea hypopnea syndrome(OSAHS). METHODS: Retrospective analysis was made of 58 test subjects at Peking University Third Hospital with suspected OSAHS who were simultaneously monitored by MPSSM and polysomnography(PSG). The PSG test results were used as the gold standard in evaluating the sensitivity and specificity of OSAHS diagnosis of MPSSM. The test result consistency of sleep apnea and hypopnea index(AHI)and total apnea time of the two methods was evaluated. Real-time waveform comparison of sleep respiratory events of a randomly selected patient diagnosed with OSAHS was performed. RESULTS: < 0.001). Bland-Altman plot showed that the consistency between the test results of the two methods was very high. CONCLUSION: As a portable, non-contact, fully automatic monitoring device, MPSSM is reliable in the screening of OSAHS compared with PSG. It is suitable to be promoted and applied in primary medical institutions, nursing homes and domestic usage. However, further research is required in improving the analysis of different sleep phase and the differentiation of central sleep apnea syndrome respiratory events in order to effectively assist medical personnel in making an accurate sleep apnea diagnosis.

Key concepts: Medicine, Polysomnography, Confidence interval, Hypopnea, Gold standard (test), Apnea, Sleep apnea, Obstructive sleep apnea

Related papers

Back to paper searchBrowse research topicsOriginal source
[Detecting of obstructive sleep apnea hypopnea syndrome using a multi-parameter pressure sensitive sleep monitor]. — Research Paper | ScholarLens