2021•INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCHRequires access

PROSPECTIVE RANDOMISED COMPARATIVE STUDY OF TENSION BAND WIRING AND OLECRANON PLATING FOR TREATMENT OF OLECRANON FRACTURES

Yogesh Malik, SK Bhaskar, Hemeshwar Harshwardhan, Brahmaji Rao, Akshit Sen

Open publisher page 0 citations

Abstract

Introduction- Olecranon fractures are one of the most commonly seen orthopedic injuries and account for approximately 10% of all proximal . forearm fractures. Operative treatment is open advocated in fractures with an articular incongruity of more than 2 mm, hence only a minority of patients are treated conservatively. The purpose of current study is to compare the clinical and radiological outcome of tension band wiring and plate xation in patients operated for olecranon fractures. Materials and methods- Current study was conducted in a tertiary care center from December 2018 to December 2020. Study compromises of 50 patients operated for olecranon fracture. Implant used -tension band wiring with 2 k wire ,1 ss wire and olecranon plate Classification used - Schatzker classication Clinical and functional outcome were assessed using mayo elbow performance score Results and observations- Study consists of 50 cases of fractures of the olecranon treated by Tension band wiring with Kirshner wire and Olecranon plate. The results were evaluated according to the Mayo elbow performance score. The results obtained in our series were excellent in 41 (82%) patients, good in 6 (12%) patients, fair in 3 (6%) patients and no poor results. Conclusion-it is concluded that the technique of open reduction and internal xation with Kirschner wires and tension band wiring and olecranon plate xation are effective means of treating fractures of olecranon.

About this research paper

What this paper is about

Introduction- Olecranon fractures are one of the most commonly seen orthopedic injuries and account for approximately 10% of all proximal . forearm fractures. Operative treatment is open advocated in fractures with an articular incongruity of more than 2 mm, hence only a minority of patients are treated conservatively. The purpose of current study is to compare the clinical and radiological outcome of tension band wiring and plate xation in patients operated for olecranon fractures. Materials and methods- Current study was conducted in a tertiary care center from December 2018 to December 2020. Study compromises of 50 patients operated for olecranon fracture. Implant used -tension band wiring with 2 k wire ,1 ss wire and olecranon plate Classification used - Schatzker classication Clinical and functional outcome were assessed using mayo elbow performance score Results and observations- Study consists of 50 cases of fractures of the olecranon treated by Tension band wiring with Kirshner wire and Olecranon plate. The results were evaluated according to the Mayo elbow performance score. The results obtained in our series were excellent in 41 (82%) patients, good in 6 (12%) patients, fair in 3 (6%) patients and no poor results. Conclusion-it is concluded that the technique of open reduction and internal xation with Kirschner wires and tension band wiring and olecranon plate xation are effective means of treating fractures of olecranon.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction- Olecranon fractures are one of the most commonly seen orthopedic injuries and account for approximately 10% of all proximal . forearm fractures. Operative treatment is open advocated in fractures with an articular incongruity of more than 2 mm, hence only a minority of patients are treated conservatively. The purpose of current study is to compare the clinical and radiological outcome of tension band wiring and plate xation in patients operated for olecranon fractures. Materials and methods- Current study was conducted in a tertiary care center from December 2018 to December 2020. Study compromises of 50 patients operated for olecranon fracture. Implant used -tension band wiring with 2 k wire ,1 ss wire and olecranon plate Classification used - Schatzker classication Clinical and functional outcome were assessed using mayo elbow performance score Results and observations- Study consists of 50 cases of fractures of the olecranon treated by Tension band wiring with Kirshner wire and Olecranon plate. The results were evaluated according to the Mayo elbow performance score. The results obtained in our series were excellent in 41 (82%) patients, good in 6 (12%) patients, fair in 3 (6%) patients and no poor results. Conclusion-it is concluded that the technique of open reduction and internal xation with Kirschner wires and tension band wiring and olecranon plate xation are effective means of treating fractures of olecranon.

Key concepts: Olecranon, Tension band wiring, Medicine, Elbow, Orthopedic surgery, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
PROSPECTIVE RANDOMISED COMPARATIVE STUDY OF TENSION BAND WIRING AND OLECRANON PLATING FOR TREATMENT OF OLECRANON FRACTURES — Research Paper | ScholarLens