A durable microsecond solid-state pulsed power system

Rong Chen, Bao-Liang Qian, Jianhua Yang, Xinbing Cheng, Jiuyuan Geng

Open publisher page 4 citations

Abstract

An all-solid-state microsecond pulsed power system has been tested in this paper. It can produce larger than 50 kV and microsecond-range pulses continuously for more than 9 × 104 shots into a resistive load at a repetition rate of 10 pps. The whole device has accumulatively operated more than 15 000 pulses at 100 Hz and 3 × 105 pulses at 10 Hz. This all-solid-state pulsed power system consists of a repetitive power supply, a four-stage Marx generator, a pulse forming network, and a resistive load. The repetitive power supply of the pulsed power system is calculated and analyzed first, followed by the introduction of the Marx generator and the three-section anti-resonance network. A polymer box of sodium chloride solution is applied as a resistive load with an impedance of 200 Ω. Repetitive experiments showed that this system is able to operate stably at 100 Hz repetition rate without failure.

About this research paper

What this paper is about

An all-solid-state microsecond pulsed power system has been tested in this paper. It can produce larger than 50 kV and microsecond-range pulses continuously for more than 9 × 104 shots into a resistive load at a repetition rate of 10 pps. The whole device has accumulatively operated more than 15 000 pulses at 100 Hz and 3 × 105 pulses at 10 Hz. This all-solid-state pulsed power system consists of a repetitive power supply, a four-stage Marx generator, a pulse forming network, and a resistive load. The repetitive power supply of the pulsed power system is calculated and analyzed first, followed by the introduction of the Marx generator and the three-section anti-resonance network. A polymer box of sodium chloride solution is applied as a resistive load with an impedance of 200 Ω. Repetitive experiments showed that this system is able to operate stably at 100 Hz repetition rate without failure.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An all-solid-state microsecond pulsed power system has been tested in this paper. It can produce larger than 50 kV and microsecond-range pulses continuously for more than 9 × 104 shots into a resistive load at a repetition rate of 10 pps. The whole device has accumulatively operated more than 15 000 pulses at 100 Hz and 3 × 105 pulses at 10 Hz. This all-solid-state pulsed power system consists of a repetitive power supply, a four-stage Marx generator, a pulse forming network, and a resistive load. The repetitive power supply of the pulsed power system is calculated and analyzed first, followed by the introduction of the Marx generator and the three-section anti-resonance network. A polymer box of sodium chloride solution is applied as a resistive load with an impedance of 200 Ω. Repetitive experiments showed that this system is able to operate stably at 100 Hz repetition rate without failure.

Key concepts: Microsecond, Pulsed power, Resistive touchscreen, Materials science, Pulse generator, Power (physics), Marx generator, Pulse (music)

Related papers

Back to paper searchBrowse research topicsOriginal source
A durable microsecond solid-state pulsed power system — Research Paper | ScholarLens