2017•Cherkasy University Bulletin: Physical and Mathematical SciencesOpen access

High-speed optical pyrometer calibration

V. V. Savina, Н. В. Сторожук

Open full text 0 citations

Abstract

The paper presents an experiment and a computer model for the high-speed optical pyrometer calibration and describes in detail the method of the experiment. The issue of high-speed pyrometer calibration was high lighted. The calibration curves for the two lamps (spiral lamp 17 V - 170 W and photometric SIRSH 6-40) were obtained as well. The article shows the brightness distribution along the spiral  length of one and a tape of other lamp. The etalon calibration by using an optical pyrometer with a disappearing filament  has been also done. Moreover, the authors describe the way how to make a computer model, and compare  it with the experiment results. According to the experiment results and the computer model data, it can be concluded that the spiral lamp can be used as a standard for the high-speed optical pyrometer calibration by following calibration procedure

About this research paper

What this paper is about

The paper presents an experiment and a computer model for the high-speed optical pyrometer calibration and describes in detail the method of the experiment. The issue of high-speed pyrometer calibration was high lighted. The calibration curves for the two lamps (spiral lamp 17 V - 170 W and photometric SIRSH 6-40) were obtained as well. The article shows the brightness distribution along the spiral  length of one and a tape of other lamp. The etalon calibration by using an optical pyrometer with a disappearing filament  has been also done. Moreover, the authors describe the way how to make a computer model, and compare  it with the experiment results. According to the experiment results and the computer model data, it can be concluded that the spiral lamp can be used as a standard for the high-speed optical pyrometer calibration by following calibration procedure

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The paper presents an experiment and a computer model for the high-speed optical pyrometer calibration and describes in detail the method of the experiment. The issue of high-speed pyrometer calibration was high lighted. The calibration curves for the two lamps (spiral lamp 17 V - 170 W and photometric SIRSH 6-40) were obtained as well. The article shows the brightness distribution along the spiral  length of one and a tape of other lamp. The etalon calibration by using an optical pyrometer with a disappearing filament  has been also done. Moreover, the authors describe the way how to make a computer model, and compare  it with the experiment results. According to the experiment results and the computer model data, it can be concluded that the spiral lamp can be used as a standard for the high-speed optical pyrometer calibration by following calibration procedure

Key concepts: Pyrometer, Calibration, Optics, Brightness, Spiral (railway), Computer science, Physics, Temperature measurement

Related papers

Back to paper searchBrowse research topicsOriginal source
High-speed optical pyrometer calibration — Research Paper | ScholarLens