Facile preparation of tetra‐ polyethylene glycol hydrogel microspheres for drug delivery by cross‐flow membrane emulsification

Jeff Henise, Brian Yao, Gary W. Ashley, Daniel V. Santi

Open full text 9 citations

Abstract

Abstract The purpose of this work was to develop technology for facile, large‐scale production of tetra‐polyethylene glycol (PEG) hydrogel amino‐microspheres to serve as intermediates for injectable microsphere‐drug conjugates produced under cGMP guidelines. Here we developed equipment and procedures utilizing tubular cross‐flow membrane emulsification to produce the amino‐microspheres. The equipment comprised a polyether ether ketone tube containing 1000 evenly spaced pores encased in a cylindrical stainless steel jacket. The dispersed phase – an aqueous solution of two polymerizable tetra‐PEG prepolymers – is delivered into the outer jacket of the assembly by a pulse dampened pump, and the continuous phase – decane and surfactant – is delivered into the bore of the microporous tube from a pressurized tank. As the dispersed phase is pressed through the pores, the continuous phase induces the detachment of small, uniform droplets of ˜60 μm diameter at the mouths of the pores. After collection of the emulsified droplets, they are allowed to self‐polymerize and are then sieved to remove aberrantly small and large particles. The polymerized amino‐microspheres – obtained in ˜70% yield – are well within acceptance specifications, and show excellent injectability. Using this approach, we could prepare about 30 L of swollen amino‐microspheres per day which could be forwarded to production of microsphere‐drug substance under cGMP guidelines.

Open-access reader

About this research paper

What this paper is about

Abstract The purpose of this work was to develop technology for facile, large‐scale production of tetra‐polyethylene glycol (PEG) hydrogel amino‐microspheres to serve as intermediates for injectable microsphere‐drug conjugates produced under cGMP guidelines. Here we developed equipment and procedures utilizing tubular cross‐flow membrane emulsification to produce the amino‐microspheres. The equipment comprised a polyether ether ketone tube containing 1000 evenly spaced pores encased in a cylindrical stainless steel jacket. The dispersed phase – an aqueous solution of two polymerizable tetra‐PEG prepolymers – is delivered into the outer jacket of the assembly by a pulse dampened pump, and the continuous phase – decane and surfactant – is delivered into the bore of the microporous tube from a pressurized tank. As the dispersed phase is pressed through the pores, the continuous phase induces the detachment of small, uniform droplets of ˜60 μm diameter at the mouths of the pores. After collection of the emulsified droplets, they are allowed to self‐polymerize and are then sieved to remove aberrantly small and large particles. The polymerized amino‐microspheres – obtained in ˜70% yield – are well within acceptance specifications, and show excellent injectability. Using this approach, we could prepare about 30 L of swollen amino‐microspheres per day which could be forwarded to production of microsphere‐drug substance under cGMP guidelines.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The purpose of this work was to develop technology for facile, large‐scale production of tetra‐polyethylene glycol (PEG) hydrogel amino‐microspheres to serve as intermediates for injectable microsphere‐drug conjugates produced under cGMP guidelines. Here we developed equipment and procedures utilizing tubular cross‐flow membrane emulsification to produce the amino‐microspheres. The equipment comprised a polyether ether ketone tube containing 1000 evenly spaced pores encased in a cylindrical stainless steel jacket. The dispersed phase – an aqueous solution of two polymerizable tetra‐PEG prepolymers – is delivered into the outer jacket of the assembly by a pulse dampened pump, and the continuous phase – decane and surfactant – is delivered into the bore of the microporous tube from a pressurized tank. As the dispersed phase is pressed through the pores, the continuous phase induces the detachment of small, uniform droplets of ˜60 μm diameter at the mouths of the pores. After collection of the emulsified droplets, they are allowed to self‐polymerize and are then sieved to remove aberrantly small and large particles. The polymerized amino‐microspheres – obtained in ˜70% yield – are well within acceptance specifications, and show excellent injectability. Using this approach, we could prepare about 30 L of swollen amino‐microspheres per day which could be forwarded to production of microsphere‐drug substance under cGMP guidelines.

Key concepts: Polyethylene glycol, Membrane emulsification, Materials science, Pulmonary surfactant, Polymerization, Chemical engineering, Microsphere, Microporous material

Related papers

Back to paper searchBrowse research topicsOriginal source
Facile preparation of tetra‐ polyethylene glycol hydrogel microspheres for drug delivery by cross‐flow membrane emulsification — Research Paper | ScholarLens