2021•Graefe s Archive for Clinical and Experimental OphthalmologyOpen access

Inter-eye relationship of intraocular pressure change after unilateral trabeculectomy, filtering canaloplasty, or PreserFlo™ microshunt implantation

Fidan A. Aghayeva, Panagiotis Chronopoulos, Alexander Karl-Georg Schuster, Norbert Pfeiffer, Esther M. Hoffmann

Open full text 19 citations

Abstract

PURPOSE: This study assesses short-term intraocular pressure (IOP) change in the fellow eye of glaucoma patients after mitomycin C-augmented trabeculectomy, filtering canaloplasty, or PreserFlo™ microshunt implantation in the treated eye. MATERIALS AND METHODS: Retrospective chart review of 235 glaucoma patients (235 eyes) was performed. Patients underwent initial trabeculectomy (187 patients), filtering canaloplasty (25 patients), or PreserFlo™ microshunt implantation (23 patients) in one eye, while the fellow eye was naïve to any previous glaucoma surgery. IOP was evaluated before and on the 1st and 2nd days and at 1 week after surgery. Main outcome measure was IOP change in the fellow eye. Secondary outcomes were proportion of clinically significant IOP elevation in the fellow eye and evaluation of potential risk factors associated with postoperative IOP fluctuation. RESULTS: IOP in the fellow eye at 1 week after trabeculectomy was statistically significantly lower than preoperatively (p < 0.0001), while the IOP did not change significantly in the fellow eyes in filtering canaloplasty or PreserFlo groups. The higher the preoperative IOP was in the fellow eye, the larger was the intraocular pressure-lowering effect at 1 week after trabeculectomy (p < 0.0001). A clinically significant IOP elevation was noted in 14.2%, 9.5%, and 5% of fellow eyes after trabeculectomy, filtering canaloplasty, or PreserFlo™ microshunt implantation, respectively. CONCLUSIONS: This study shows an IOP-lowering effect in the fellow eye of glaucoma patients after trabeculectomy. Significant IOP rise might occur in the fellow eye of some glaucoma patients after different types of glaucoma surgery.

Open-access reader

About this research paper

What this paper is about

PURPOSE: This study assesses short-term intraocular pressure (IOP) change in the fellow eye of glaucoma patients after mitomycin C-augmented trabeculectomy, filtering canaloplasty, or PreserFlo™ microshunt implantation in the treated eye. MATERIALS AND METHODS: Retrospective chart review of 235 glaucoma patients (235 eyes) was performed. Patients underwent initial trabeculectomy (187 patients), filtering canaloplasty (25 patients), or PreserFlo™ microshunt implantation (23 patients) in one eye, while the fellow eye was naïve to any previous glaucoma surgery. IOP was evaluated before and on the 1st and 2nd days and at 1 week after surgery. Main outcome measure was IOP change in the fellow eye. Secondary outcomes were proportion of clinically significant IOP elevation in the fellow eye and evaluation of potential risk factors associated with postoperative IOP fluctuation. RESULTS: IOP in the fellow eye at 1 week after trabeculectomy was statistically significantly lower than preoperatively (p < 0.0001), while the IOP did not change significantly in the fellow eyes in filtering canaloplasty or PreserFlo groups. The higher the preoperative IOP was in the fellow eye, the larger was the intraocular pressure-lowering effect at 1 week after trabeculectomy (p < 0.0001). A clinically significant IOP elevation was noted in 14.2%, 9.5%, and 5% of fellow eyes after trabeculectomy, filtering canaloplasty, or PreserFlo™ microshunt implantation, respectively. CONCLUSIONS: This study shows an IOP-lowering effect in the fellow eye of glaucoma patients after trabeculectomy. Significant IOP rise might occur in the fellow eye of some glaucoma patients after different types of glaucoma surgery.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: This study assesses short-term intraocular pressure (IOP) change in the fellow eye of glaucoma patients after mitomycin C-augmented trabeculectomy, filtering canaloplasty, or PreserFlo™ microshunt implantation in the treated eye. MATERIALS AND METHODS: Retrospective chart review of 235 glaucoma patients (235 eyes) was performed. Patients underwent initial trabeculectomy (187 patients), filtering canaloplasty (25 patients), or PreserFlo™ microshunt implantation (23 patients) in one eye, while the fellow eye was naïve to any previous glaucoma surgery. IOP was evaluated before and on the 1st and 2nd days and at 1 week after surgery. Main outcome measure was IOP change in the fellow eye. Secondary outcomes were proportion of clinically significant IOP elevation in the fellow eye and evaluation of potential risk factors associated with postoperative IOP fluctuation. RESULTS: IOP in the fellow eye at 1 week after trabeculectomy was statistically significantly lower than preoperatively (p < 0.0001), while the IOP did not change significantly in the fellow eyes in filtering canaloplasty or PreserFlo groups. The higher the preoperative IOP was in the fellow eye, the larger was the intraocular pressure-lowering effect at 1 week after trabeculectomy (p < 0.0001). A clinically significant IOP elevation was noted in 14.2%, 9.5%, and 5% of fellow eyes after trabeculectomy, filtering canaloplasty, or PreserFlo™ microshunt implantation, respectively. CONCLUSIONS: This study shows an IOP-lowering effect in the fellow eye of glaucoma patients after trabeculectomy. Significant IOP rise might occur in the fellow eye of some glaucoma patients after different types of glaucoma surgery.

Key concepts: Trabeculectomy, Medicine, Intraocular pressure, Glaucoma, Ophthalmology, Glaucoma surgery, Eye disease, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Inter-eye relationship of intraocular pressure change after unilateral trabeculectomy, filtering canaloplasty, or PreserFlo™ microshunt implantation — Research Paper | ScholarLens