2021Malaysian Journal of Applied SciencesOpen access

Ambient Air Measurement of Benzene, Toluene and Xylene Within a Nigerian Petroleum Products Depot and Its Host Environment Using Carbon Adsorption and GC-FID Techniques

Ismail Muhibbu-din

Open full text 0 citations

Abstract

Health effects of benzene, toluene and xylene emissions from a Nigerian Petroleum Products depot make stringent adherence to maximum allowable concentration very important. The storage facilities and distribution network and other installations of petroleum products depot are significant sources of benzene, toluene and xylene therefore ambient air of the depot requires observation and assessment. The ambient air concentrations of BTX were been measured within Pipelines and Product Marketing Company, Mosimi Depot and its immediate environment. Air samples were collected on granular activated charcoal through low volume air sampler and extracted with carbon disulphide (CS2) by desorption process.The extracted solutions were subjected to Flame Ionization Detection analysis in a gas chromatograph (Model: HP 6890) using a capillary column HP 5MS with length, inner diameter and particle size set at 30 m × 0.25 mm × 0.25 μm. The gas chromatograph was powered with chemstation RevA09.01 [1206] software to determine the concentrations of each of the identified VOCs species. The concentrations of benzene, toluene, p xylene, m xylene and o xylene ranged between 0.0104 - 0.0711, 0.0019 - 0.0998, 0.0010 - 0.0022, 0.0014 - 0.0026 and 0.0006 0.0019 mg/m3 respectively. The mean values were 0.0277, 0.0389, 0.0013, 0.0019 and 0.00010 mg/m3, respectively. On the average, the observed concentrations did not exceed the tolerance (air concentrations) limits set for Nigeria environment by the National Environmental Standards and Regulations Enforcement Agency (NESREA).

Open-access reader

About this research paper

What this paper is about

Health effects of benzene, toluene and xylene emissions from a Nigerian Petroleum Products depot make stringent adherence to maximum allowable concentration very important. The storage facilities and distribution network and other installations of petroleum products depot are significant sources of benzene, toluene and xylene therefore ambient air of the depot requires observation and assessment. The ambient air concentrations of BTX were been measured within Pipelines and Product Marketing Company, Mosimi Depot and its immediate environment. Air samples were collected on granular activated charcoal through low volume air sampler and extracted with carbon disulphide (CS2) by desorption process.The extracted solutions were subjected to Flame Ionization Detection analysis in a gas chromatograph (Model: HP 6890) using a capillary column HP 5MS with length, inner diameter and particle size set at 30 m × 0.25 mm × 0.25 μm. The gas chromatograph was powered with chemstation RevA09.01 [1206] software to determine the concentrations of each of the identified VOCs species. The concentrations of benzene, toluene, p xylene, m xylene and o xylene ranged between 0.0104 - 0.0711, 0.0019 - 0.0998, 0.0010 - 0.0022, 0.0014 - 0.0026 and 0.0006 0.0019 mg/m3 respectively. The mean values were 0.0277, 0.0389, 0.0013, 0.0019 and 0.00010 mg/m3, respectively. On the average, the observed concentrations did not exceed the tolerance (air concentrations) limits set for Nigeria environment by the National Environmental Standards and Regulations Enforcement Agency (NESREA).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Health effects of benzene, toluene and xylene emissions from a Nigerian Petroleum Products depot make stringent adherence to maximum allowable concentration very important. The storage facilities and distribution network and other installations of petroleum products depot are significant sources of benzene, toluene and xylene therefore ambient air of the depot requires observation and assessment. The ambient air concentrations of BTX were been measured within Pipelines and Product Marketing Company, Mosimi Depot and its immediate environment. Air samples were collected on granular activated charcoal through low volume air sampler and extracted with carbon disulphide (CS2) by desorption process.The extracted solutions were subjected to Flame Ionization Detection analysis in a gas chromatograph (Model: HP 6890) using a capillary column HP 5MS with length, inner diameter and particle size set at 30 m × 0.25 mm × 0.25 μm. The gas chromatograph was powered with chemstation RevA09.01 [1206] software to determine the concentrations of each of the identified VOCs species. The concentrations of benzene, toluene, p xylene, m xylene and o xylene ranged between 0.0104 - 0.0711, 0.0019 - 0.0998, 0.0010 - 0.0022, 0.0014 - 0.0026 and 0.0006 0.0019 mg/m3 respectively. The mean values were 0.0277, 0.0389, 0.0013, 0.0019 and 0.00010 mg/m3, respectively. On the average, the observed concentrations did not exceed the tolerance (air concentrations) limits set for Nigeria environment by the National Environmental Standards and Regulations Enforcement Agency (NESREA).

Key concepts: Toluene, Benzene, Activated carbon, Xylene, Chemistry, Adsorption, Flame ionization detector, Gas chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Ambient Air Measurement of Benzene, Toluene and Xylene Within a Nigerian Petroleum Products Depot and Its Host Environment Using Carbon Adsorption and GC-FID Techniques — Research Paper | ScholarLens