2020Journal of Critical ReviewsOpen access

AN ANALYSIS OF VISCOUS DAMPERS IMPACT ON CONTROLLING THE VIBRATIONS IMPOSED ONSEISMIC VIBRATIONS

Mohammad Reza Arefi

Open full text 0 citations

Abstract

In the present paper, the impacts of viscous dampers on controlling the vibrations imposed on seismic vibrations are evaluated using descriptive method. To this end, library method and other researches related to viscous dampers and their impacts on controlling the external excitation such as earthquake have been used. ETABS software was used for modeling the structures. Also, nonlinear dynamic analysis was used for seismic analysis of the structures. Based on the findings, using viscous dampers are effective to improve seismic parameters of structure and to decreasedisplacement, speed, base shear, and velocity. On the other hand, viscous fluid dampers can strengthen structure and its performance during severe earthquakes and can be applied in newly constructed structures. The impact of passive viscous damper on reducing seismic response of the structures is found significant at the confidence level of 90%.Reduction of energy of structure hysteresis because of the nonlinear behavior of members using dampers is proved to be significant at the confidence level of 80%.The results reveal that the lateral resistance of an EBF with short joint can be 4/5 to 9 times more than the lateral resistance of a MRF, that behavior coefficient of fifteen-story EBF considered 6/5-7/75, concluded that the length of the bray does not have an impact on the behavior coefficient of these frames.

About this research paper

What this paper is about

In the present paper, the impacts of viscous dampers on controlling the vibrations imposed on seismic vibrations are evaluated using descriptive method. To this end, library method and other researches related to viscous dampers and their impacts on controlling the external excitation such as earthquake have been used. ETABS software was used for modeling the structures. Also, nonlinear dynamic analysis was used for seismic analysis of the structures. Based on the findings, using viscous dampers are effective to improve seismic parameters of structure and to decreasedisplacement, speed, base shear, and velocity. On the other hand, viscous fluid dampers can strengthen structure and its performance during severe earthquakes and can be applied in newly constructed structures. The impact of passive viscous damper on reducing seismic response of the structures is found significant at the confidence level of 90%.Reduction of energy of structure hysteresis because of the nonlinear behavior of members using dampers is proved to be significant at the confidence level of 80%.The results reveal that the lateral resistance of an EBF with short joint can be 4/5 to 9 times more than the lateral resistance of a MRF, that behavior coefficient of fifteen-story EBF considered 6/5-7/75, concluded that the length of the bray does not have an impact on the behavior coefficient of these frames.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the present paper, the impacts of viscous dampers on controlling the vibrations imposed on seismic vibrations are evaluated using descriptive method. To this end, library method and other researches related to viscous dampers and their impacts on controlling the external excitation such as earthquake have been used. ETABS software was used for modeling the structures. Also, nonlinear dynamic analysis was used for seismic analysis of the structures. Based on the findings, using viscous dampers are effective to improve seismic parameters of structure and to decreasedisplacement, speed, base shear, and velocity. On the other hand, viscous fluid dampers can strengthen structure and its performance during severe earthquakes and can be applied in newly constructed structures. The impact of passive viscous damper on reducing seismic response of the structures is found significant at the confidence level of 90%.Reduction of energy of structure hysteresis because of the nonlinear behavior of members using dampers is proved to be significant at the confidence level of 80%.The results reveal that the lateral resistance of an EBF with short joint can be 4/5 to 9 times more than the lateral resistance of a MRF, that behavior coefficient of fifteen-story EBF considered 6/5-7/75, concluded that the length of the bray does not have an impact on the behavior coefficient of these frames.

Key concepts: Damper, Vibration, Structural engineering, Nonlinear system, Vibration control, Reduction (mathematics), Engineering, Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
AN ANALYSIS OF VISCOUS DAMPERS IMPACT ON CONTROLLING THE VIBRATIONS IMPOSED ONSEISMIC VIBRATIONS — Research Paper | ScholarLens