1956•NASA STI Repository (National Aeronautics and Space Administration)Requires access

Performance Characteristics of an Axial-flow Transonic Compressor Operating up to Tip Relative Inlet Mach Number of 1.34

John W. R. Creagh

Open publisher page 1 citations

Abstract

Performance data are presented for a transonic axial-flow compressor rotor designed to operate at a tip speed of 1300 ft/sec with maximum relative tip Mach number of 1.37. The compressor had an inlet diameter of 16 inches, a hub-tip diameter ratio of 0.5 and design specific weight flow of 31.1 (lb/sec/(sq ft frontal area). Experimental values of relative total-pressure-loss coefficient were considerably higher than the assumed values. This disparity, hub choking, and application of the simple radial-equilibrium concept are discussed. The data of this report are used to extend previously presented correlation plots of compressor design parameters to higher Mach numbers.

About this research paper

What this paper is about

Performance data are presented for a transonic axial-flow compressor rotor designed to operate at a tip speed of 1300 ft/sec with maximum relative tip Mach number of 1.37. The compressor had an inlet diameter of 16 inches, a hub-tip diameter ratio of 0.5 and design specific weight flow of 31.1 (lb/sec/(sq ft frontal area). Experimental values of relative total-pressure-loss coefficient were considerably higher than the assumed values. This disparity, hub choking, and application of the simple radial-equilibrium concept are discussed. The data of this report are used to extend previously presented correlation plots of compressor design parameters to higher Mach numbers.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Performance data are presented for a transonic axial-flow compressor rotor designed to operate at a tip speed of 1300 ft/sec with maximum relative tip Mach number of 1.37. The compressor had an inlet diameter of 16 inches, a hub-tip diameter ratio of 0.5 and design specific weight flow of 31.1 (lb/sec/(sq ft frontal area). Experimental values of relative total-pressure-loss coefficient were considerably higher than the assumed values. This disparity, hub choking, and application of the simple radial-equilibrium concept are discussed. The data of this report are used to extend previously presented correlation plots of compressor design parameters to higher Mach numbers.

Key concepts: Mach number, Transonic, Gas compressor, Axial compressor, Inlet, Mechanics, Overall pressure ratio, Rotor (electric)

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance Characteristics of an Axial-flow Transonic Compressor Operating up to Tip Relative Inlet Mach Number of 1.34 — Research Paper | ScholarLens