2021IOP Conference Series Earth and Environmental ScienceOpen access

Turbidity reduction by household scale electrocoagulation device

Evi Afiatun, Hary Pradiko, R. D. Puspita

Open full text 0 citations

Abstract

Abstract Pollutant parameter that often exceed the standard is turbidity, then the turbidity parameter was the main concern in this research. The electrocoagulation method is an alternative for treating water without using chemicals. This study aims to reduce the turbidity and develop previous research on electrocoagulation methods into a pilot scale with a flow rate of 0.01 L/sec. The flow rate 0.01 L/sec illustrates the water requirements for one household. In this study the electrocoagulation method was tested by the variation of electrode plates 1, 2 and 3 pairs with 3, 5, 7 and 10 Volts to treat artificial sample water with an initial turbidity of 100 NTU made from sample of raw water from Cikapundung River as one of main drinking water sources in Bandung. The optimal conditions obtained in the preliminary study were retested with turbidity variations of 25, 50, 100, 200, 300 and 400 NTU. The optimal condition of the electrocoagulation process is obtained in the variation of 2 pairs of plates with a voltage of 7 Volts and current density 23.53 A/m2. The variation can treat raw water with an initial turbidity up to 400 NTU until it reaches a quality standard with a final turbidity of 3.40 NTU and the percentage of removal is 99.15%.

Open-access reader

About this research paper

What this paper is about

Abstract Pollutant parameter that often exceed the standard is turbidity, then the turbidity parameter was the main concern in this research. The electrocoagulation method is an alternative for treating water without using chemicals. This study aims to reduce the turbidity and develop previous research on electrocoagulation methods into a pilot scale with a flow rate of 0.01 L/sec. The flow rate 0.01 L/sec illustrates the water requirements for one household. In this study the electrocoagulation method was tested by the variation of electrode plates 1, 2 and 3 pairs with 3, 5, 7 and 10 Volts to treat artificial sample water with an initial turbidity of 100 NTU made from sample of raw water from Cikapundung River as one of main drinking water sources in Bandung. The optimal conditions obtained in the preliminary study were retested with turbidity variations of 25, 50, 100, 200, 300 and 400 NTU. The optimal condition of the electrocoagulation process is obtained in the variation of 2 pairs of plates with a voltage of 7 Volts and current density 23.53 A/m2. The variation can treat raw water with an initial turbidity up to 400 NTU until it reaches a quality standard with a final turbidity of 3.40 NTU and the percentage of removal is 99.15%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Pollutant parameter that often exceed the standard is turbidity, then the turbidity parameter was the main concern in this research. The electrocoagulation method is an alternative for treating water without using chemicals. This study aims to reduce the turbidity and develop previous research on electrocoagulation methods into a pilot scale with a flow rate of 0.01 L/sec. The flow rate 0.01 L/sec illustrates the water requirements for one household. In this study the electrocoagulation method was tested by the variation of electrode plates 1, 2 and 3 pairs with 3, 5, 7 and 10 Volts to treat artificial sample water with an initial turbidity of 100 NTU made from sample of raw water from Cikapundung River as one of main drinking water sources in Bandung. The optimal conditions obtained in the preliminary study were retested with turbidity variations of 25, 50, 100, 200, 300 and 400 NTU. The optimal condition of the electrocoagulation process is obtained in the variation of 2 pairs of plates with a voltage of 7 Volts and current density 23.53 A/m2. The variation can treat raw water with an initial turbidity up to 400 NTU until it reaches a quality standard with a final turbidity of 3.40 NTU and the percentage of removal is 99.15%.

Key concepts: Turbidity, Electrocoagulation, Environmental science, Raw water, Pulp and paper industry, Water quality, Environmental engineering, Biology