2021•NeuroImageOpen access

Temperature dependence and histological correlation of inhomogeneous magnetization transfer and myelin water imaging in ex vivo brain

Valentin Prévost, Andrew C. Yung, Sarah R. Morris, Irene M. Vavasour, Zahra Samadi‐Bahrami, G. R. Wayne Moore, Cornelia Laule, Alex L. MacKay, Piotr Kozłowski

Open full text 20 citations

Abstract

The promise of inhomogeneous magnetization transfer (ihMT) as a new myelin imaging method was studied in ex vivo human brain tissue and in relation to myelin water fraction (MWF). The temperature dependence of both methods was characterized, as well as their correspondence with a histological measure of myelin content. Unfiltered and filtered ihMT protocols were studied by adjusting the saturation scheme to preserve or attenuate signal from tissue with short dipolar relaxation time T1D. ihMT ratio (ihMTR) and MWF maps were acquired at 7 T from formalin-fixed human brain samples at 22.5 °C, 30 °C and 37 °C. The impact of temperature on unfiltered ihMTR, filtered ihMTR and MWF was investigated and compared to myelin basic protein staining. Unfiltered ihMTR exhibited no temperature dependence, whereas filtered ihMTR increased with increasing temperature. MWF decreased at higher temperature, with an increasing prevalence of areas where the myelin water signal was unreliably determined, likely related to a reduction in T2 peak separability at higher temperatures ex vivo. MWF and ihMTR showed similar per-sample correlation with myelin staining at room temperature. At 37 °C, filtered ihMTR was more strongly correlated with myelin staining and had increased dynamic range compared to unfiltered ihMTR. Given the temperature dependence of filtered ihMT, increased dynamic range, and strong myelin specificity that persists at higher temperatures, we recommend carefully controlled temperatures close to 37 °C for filtered ihMT acquisitions. Unfiltered ihMT may also be useful, due to its independence from temperature, higher amplitude values, and sensitivity to short T1D components. Ex vivo myelin water imaging should be performed at room temperature, to avoid fitting issues found at higher temperatures.

Open-access reader

About this research paper

What this paper is about

The promise of inhomogeneous magnetization transfer (ihMT) as a new myelin imaging method was studied in ex vivo human brain tissue and in relation to myelin water fraction (MWF). The temperature dependence of both methods was characterized, as well as their correspondence with a histological measure of myelin content. Unfiltered and filtered ihMT protocols were studied by adjusting the saturation scheme to preserve or attenuate signal from tissue with short dipolar relaxation time T1D. ihMT ratio (ihMTR) and MWF maps were acquired at 7 T from formalin-fixed human brain samples at 22.5 °C, 30 °C and 37 °C. The impact of temperature on unfiltered ihMTR, filtered ihMTR and MWF was investigated and compared to myelin basic protein staining. Unfiltered ihMTR exhibited no temperature dependence, whereas filtered ihMTR increased with increasing temperature. MWF decreased at higher temperature, with an increasing prevalence of areas where the myelin water signal was unreliably determined, likely related to a reduction in T2 peak separability at higher temperatures ex vivo. MWF and ihMTR showed similar per-sample correlation with myelin staining at room temperature. At 37 °C, filtered ihMTR was more strongly correlated with myelin staining and had increased dynamic range compared to unfiltered ihMTR. Given the temperature dependence of filtered ihMT, increased dynamic range, and strong myelin specificity that persists at higher temperatures, we recommend carefully controlled temperatures close to 37 °C for filtered ihMT acquisitions. Unfiltered ihMT may also be useful, due to its independence from temperature, higher amplitude values, and sensitivity to short T1D components. Ex vivo myelin water imaging should be performed at room temperature, to avoid fitting issues found at higher temperatures.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The promise of inhomogeneous magnetization transfer (ihMT) as a new myelin imaging method was studied in ex vivo human brain tissue and in relation to myelin water fraction (MWF). The temperature dependence of both methods was characterized, as well as their correspondence with a histological measure of myelin content. Unfiltered and filtered ihMT protocols were studied by adjusting the saturation scheme to preserve or attenuate signal from tissue with short dipolar relaxation time T1D. ihMT ratio (ihMTR) and MWF maps were acquired at 7 T from formalin-fixed human brain samples at 22.5 °C, 30 °C and 37 °C. The impact of temperature on unfiltered ihMTR, filtered ihMTR and MWF was investigated and compared to myelin basic protein staining. Unfiltered ihMTR exhibited no temperature dependence, whereas filtered ihMTR increased with increasing temperature. MWF decreased at higher temperature, with an increasing prevalence of areas where the myelin water signal was unreliably determined, likely related to a reduction in T2 peak separability at higher temperatures ex vivo. MWF and ihMTR showed similar per-sample correlation with myelin staining at room temperature. At 37 °C, filtered ihMTR was more strongly correlated with myelin staining and had increased dynamic range compared to unfiltered ihMTR. Given the temperature dependence of filtered ihMT, increased dynamic range, and strong myelin specificity that persists at higher temperatures, we recommend carefully controlled temperatures close to 37 °C for filtered ihMT acquisitions. Unfiltered ihMT may also be useful, due to its independence from temperature, higher amplitude values, and sensitivity to short T1D components. Ex vivo myelin water imaging should be performed at room temperature, to avoid fitting issues found at higher temperatures.

Key concepts: Myelin, Magnetization transfer, Ex vivo, Nuclear magnetic resonance, Chemistry, In vivo, White matter, Relaxation (psychology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Temperature dependence and histological correlation of inhomogeneous magnetization transfer and myelin water imaging in ex vivo brain — Research Paper | ScholarLens