2014Optics and Precision EngineeringRequires access

Calibration of 1m aperture infrared theodolite

LI Nin

Open publisher page 0 citations

Abstract

To measure infrared radiation characteristics of air targets,the calibration system for a 1maperture infrared measurement system was designed.A mathematic model of calibration for the infrared measurement system was given and a radiometric calibration system was established by combinations of a cavity blackbody and a collimator as the standard radiation source.Because the spectral response of the infrared measuring system is selective,the calibration principle based on conventional radiometric calibration method has theoretical errors and reduces the precision of radiometric calibration.To solve the problem,a relative spectral calibration method based on a monochromator and a standard radiometer was proposed.The mathematical model was given and a relative spectral calibration was performed.Finally,the experiments on radiation characteristic measurement were performed in the field by using the blackbody as a simulated target.The results show that the measurement max error from the 1maperture infrared radiation characteristic measurement system is9.5%and improves by an average of 8.7%as compared with that of the conventional method.These show that the proposed method meets the requirements of practical applications and is suitable for the radiometric calibration in the out-fields.

About this research paper

What this paper is about

To measure infrared radiation characteristics of air targets,the calibration system for a 1maperture infrared measurement system was designed.A mathematic model of calibration for the infrared measurement system was given and a radiometric calibration system was established by combinations of a cavity blackbody and a collimator as the standard radiation source.Because the spectral response of the infrared measuring system is selective,the calibration principle based on conventional radiometric calibration method has theoretical errors and reduces the precision of radiometric calibration.To solve the problem,a relative spectral calibration method based on a monochromator and a standard radiometer was proposed.The mathematical model was given and a relative spectral calibration was performed.Finally,the experiments on radiation characteristic measurement were performed in the field by using the blackbody as a simulated target.The results show that the measurement max error from the 1maperture infrared radiation characteristic measurement system is9.5%and improves by an average of 8.7%as compared with that of the conventional method.These show that the proposed method meets the requirements of practical applications and is suitable for the radiometric calibration in the out-fields.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To measure infrared radiation characteristics of air targets,the calibration system for a 1maperture infrared measurement system was designed.A mathematic model of calibration for the infrared measurement system was given and a radiometric calibration system was established by combinations of a cavity blackbody and a collimator as the standard radiation source.Because the spectral response of the infrared measuring system is selective,the calibration principle based on conventional radiometric calibration method has theoretical errors and reduces the precision of radiometric calibration.To solve the problem,a relative spectral calibration method based on a monochromator and a standard radiometer was proposed.The mathematical model was given and a relative spectral calibration was performed.Finally,the experiments on radiation characteristic measurement were performed in the field by using the blackbody as a simulated target.The results show that the measurement max error from the 1maperture infrared radiation characteristic measurement system is9.5%and improves by an average of 8.7%as compared with that of the conventional method.These show that the proposed method meets the requirements of practical applications and is suitable for the radiometric calibration in the out-fields.

Key concepts: Calibration, Theodolite, Radiometer, Black-body radiation, Infrared, Monochromator, Optics, Remote sensing

Related papers

Back to paper searchBrowse research topicsOriginal source
Calibration of 1m aperture infrared theodolite — Research Paper | ScholarLens