The effect of chemical ablation of the endocardium on ventricular fibrillation threshold.
R JDamiano, P KSmith, H FTripp, TAsano, K WSmall, J ELowe, R EIdeker, J LCox
Abstract
R JDamiano, P KSmith, H FTripp, TAsano, K WSmall, J ELowe, R EIdeker, J LCox
Abstract
The purpose of this study was to examine the effects of ablation of the superficial endocardium and Purkinje network on left ventricular fibrillation threshold. Lugol's solution was applied through small ventriculotomies to the left and right ventricular endocardium of 10 dogs on cardiopulmonary bypass. Two control groups of five animals each underwent either endocardial application of saline or epicardial application of Lugol's solution. Ventricular fibrillation threshold was measured before and after each intervention by the single-stimulus technique. Application of Lugol's solution to the endocardium resulted in a 102 +/- 15% increase in ventricular fibrillation threshold from a control value of 26 +/- 2 to 53 +/- 6 mA (p less than .005). In two animals, ventricular fibrillation could not be initiated postoperatively. In the control groups, there were no significant changes in ventricular fibrillation threshold. Histologic examination revealed that Lugol's solution obliterated less than 0.5 mm of super...
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The purpose of this study was to examine the effects of ablation of the superficial endocardium and Purkinje network on left ventricular fibrillation threshold. Lugol's solution was applied through small ventriculotomies to the left and right ventricular endocardium of 10 dogs on cardiopulmonary bypass. Two control groups of five animals each underwent either endocardial application of saline or epicardial application of Lugol's solution. Ventricular fibrillation threshold was measured before and after each intervention by the single-stimulus technique. Application of Lugol's solution to the endocardium resulted in a 102 +/- 15% increase in ventricular fibrillation threshold from a control value of 26 +/- 2 to 53 +/- 6 mA (p less than .005). In two animals, ventricular fibrillation could not be initiated postoperatively. In the control groups, there were no significant changes in ventricular fibrillation threshold. Histologic examination revealed that Lugol's solution obliterated less than 0.5 mm of super...
Key concepts: Endocardium, Medicine, Ventricular fibrillation, Cardiology, Internal medicine, Ablation, Cardiopulmonary bypass, Fibrillation