2010•Institutional Repositories DataBase (IRDB)Open access

Acceleration Test of Two-Beam Type IH-RFQ Linac

Takuya Ishibashi, T. Hattori, Noriyosu Hayashizaki, Liang, L.

Open full text 0 citations

Abstract

High intensity heavy ion beam acceleration in the low energy region is one of the most difficult conditions to achieve, because the space charge effect is extremely strong. In order to generate a high intensity beam using linacs, we have to avoid beam loss by the space charge effect as much as possible. Multibeam acceleration has been proposed as a possible method of reducing the space charge effect. If one cavity could be used to accelerate several beams, a significant gain would be made in installation space and operational cost saving. In this study we look at a multibeam type radio frequency quadrupole (RFQ) linac in order to accelerate several beams using a single cavity. The RFQ electrodes are placed in an IH type cavity; This structure is known as a IH-RFQ linac. GSI in Germany proposed a multibeam type IH-RFQ linac with several beam channels in a single cavity. However, this multibeam type IH-RFQ linac has yet to be manufactured. We manufactured a 2-beam type IH-RFQ linac as a prototype of the multibeam type IH-RFQ. The linac outputs C²⁺ beam of 60 keV/u and 44 mA/channel in the design value. We will report about the beam acceleration test of the linac.

About this research paper

What this paper is about

High intensity heavy ion beam acceleration in the low energy region is one of the most difficult conditions to achieve, because the space charge effect is extremely strong. In order to generate a high intensity beam using linacs, we have to avoid beam loss by the space charge effect as much as possible. Multibeam acceleration has been proposed as a possible method of reducing the space charge effect. If one cavity could be used to accelerate several beams, a significant gain would be made in installation space and operational cost saving. In this study we look at a multibeam type radio frequency quadrupole (RFQ) linac in order to accelerate several beams using a single cavity. The RFQ electrodes are placed in an IH type cavity; This structure is known as a IH-RFQ linac. GSI in Germany proposed a multibeam type IH-RFQ linac with several beam channels in a single cavity. However, this multibeam type IH-RFQ linac has yet to be manufactured. We manufactured a 2-beam type IH-RFQ linac as a prototype of the multibeam type IH-RFQ. The linac outputs C²⁺ beam of 60 keV/u and 44 mA/channel in the design value. We will report about the beam acceleration test of the linac.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

High intensity heavy ion beam acceleration in the low energy region is one of the most difficult conditions to achieve, because the space charge effect is extremely strong. In order to generate a high intensity beam using linacs, we have to avoid beam loss by the space charge effect as much as possible. Multibeam acceleration has been proposed as a possible method of reducing the space charge effect. If one cavity could be used to accelerate several beams, a significant gain would be made in installation space and operational cost saving. In this study we look at a multibeam type radio frequency quadrupole (RFQ) linac in order to accelerate several beams using a single cavity. The RFQ electrodes are placed in an IH type cavity; This structure is known as a IH-RFQ linac. GSI in Germany proposed a multibeam type IH-RFQ linac with several beam channels in a single cavity. However, this multibeam type IH-RFQ linac has yet to be manufactured. We manufactured a 2-beam type IH-RFQ linac as a prototype of the multibeam type IH-RFQ. The linac outputs C²⁺ beam of 60 keV/u and 44 mA/channel in the design value. We will report about the beam acceleration test of the linac.

Key concepts: Linear particle accelerator, Acceleration, Beam (structure), Physics, Optics, Classical mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Acceleration Test of Two-Beam Type IH-RFQ Linac — Research Paper | ScholarLens