Acceleration Test of Two-Beam Type IH-RFQ Linac
Takuya Ishibashi, T. Hattori, Noriyosu Hayashizaki, Liang, L.
Abstract
Takuya Ishibashi, T. Hattori, Noriyosu Hayashizaki, Liang, L.
Abstract
High intensity heavy ion beam acceleration in the low energy region is one of the most difficult conditions to achieve, because the space charge effect is extremely strong. In order to generate a high intensity beam using linacs, we have to avoid beam loss by the space charge effect as much as possible. Multibeam acceleration has been proposed as a possible method of reducing the space charge effect. If one cavity could be used to accelerate several beams, a significant gain would be made in installation space and operational cost saving. In this study we look at a multibeam type radio frequency quadrupole (RFQ) linac in order to accelerate several beams using a single cavity. The RFQ electrodes are placed in an IH type cavity; This structure is known as a IH-RFQ linac. GSI in Germany proposed a multibeam type IH-RFQ linac with several beam channels in a single cavity. However, this multibeam type IH-RFQ linac has yet to be manufactured. We manufactured a 2-beam type IH-RFQ linac as a prototype of the multibeam type IH-RFQ. The linac outputs C²⁺ beam of 60 keV/u and 44 mA/channel in the design value. We will report about the beam acceleration test of the linac.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
High intensity heavy ion beam acceleration in the low energy region is one of the most difficult conditions to achieve, because the space charge effect is extremely strong. In order to generate a high intensity beam using linacs, we have to avoid beam loss by the space charge effect as much as possible. Multibeam acceleration has been proposed as a possible method of reducing the space charge effect. If one cavity could be used to accelerate several beams, a significant gain would be made in installation space and operational cost saving. In this study we look at a multibeam type radio frequency quadrupole (RFQ) linac in order to accelerate several beams using a single cavity. The RFQ electrodes are placed in an IH type cavity; This structure is known as a IH-RFQ linac. GSI in Germany proposed a multibeam type IH-RFQ linac with several beam channels in a single cavity. However, this multibeam type IH-RFQ linac has yet to be manufactured. We manufactured a 2-beam type IH-RFQ linac as a prototype of the multibeam type IH-RFQ. The linac outputs C²⁺ beam of 60 keV/u and 44 mA/channel in the design value. We will report about the beam acceleration test of the linac.
Key concepts: Linear particle accelerator, Acceleration, Beam (structure), Physics, Optics, Classical mechanics