Quantification of ultrasound emboli signals in patients with cardiac and carotid disease.
D GGrosset, DGeorgiadis, A WKelman, K RLees
Abstract
D GGrosset, DGeorgiadis, A WKelman, K RLees
Abstract
The use of Doppler ultrasound to detect arterial emboli has major implications for the classification and treatment of stroke. Experimental studies indicate that embolic materials produce different ultrasound signals, depending on their acoustic properties. To examine the possibility of characterizing emboli of different sources in the clinical setting, we compared the emboli signals of patients with cardiac embolic sources with those of patients with signals of carotid embolic sources.Transcranial Doppler monitoring (30 minutes per patient) of the middle cerebral arteries was performed in 80 patients with prosthetic cardiac valves and 20 patients with internal carotid artery stenosis. The signal power of emboli was calculated in relation to the background Doppler signal.In patients who were embolizing from prosthetic heart valves, the frequency of embolus signals was greater than in patients with carotid stenosis who were embolizing (mean +/- SEM: 58.2 +/- 11 versus 8.2 +/- 3 signals per hour; P < .0001,...
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The use of Doppler ultrasound to detect arterial emboli has major implications for the classification and treatment of stroke. Experimental studies indicate that embolic materials produce different ultrasound signals, depending on their acoustic properties. To examine the possibility of characterizing emboli of different sources in the clinical setting, we compared the emboli signals of patients with cardiac embolic sources with those of patients with signals of carotid embolic sources.Transcranial Doppler monitoring (30 minutes per patient) of the middle cerebral arteries was performed in 80 patients with prosthetic cardiac valves and 20 patients with internal carotid artery stenosis. The signal power of emboli was calculated in relation to the background Doppler signal.In patients who were embolizing from prosthetic heart valves, the frequency of embolus signals was greater than in patients with carotid stenosis who were embolizing (mean +/- SEM: 58.2 +/- 11 versus 8.2 +/- 3 signals per hour; P < .0001,...
Key concepts: Medicine, Embolus, Transcranial Doppler, Stenosis, Ultrasound, Radiology, Cardiology, Stroke (engine)