2000•Academic Journal of Sun Yat-sen University of Medical SciencesRequires access

The Investigation of Non scintillation Liquid Counting on ~(32)P

Xiu Liu

Open publisher page 0 citations

Abstract

Objective Investigate a rapid、accurate method of scintillation and non scintillation liquid on counting the radioactivity of 32 P. Methods According to the theory of Cerenkov radiation, different counting medium and condition on 32 P were studied. Results ① In different counting medium, the counting efficiency of non scintillation liquid in water, air and filter paper were 84%,67% and 60% of the scintillation liquid efficiency respectively.② Different vials: The plastic vials dealed with scintillation liquid had the highest counting efficiency, while the ordinary plastic and glass vials were 69% and 50% respectly. ③ The volume of samples (from 30 uL to 10 mL): the counting results of the samples of defferent volume were not significant change (P0.05). Conclusion The “dry” counting of 32 P by plastic vials dealed with scintillation liquid can obtain the highest counting efficiency, and can be used repeatly.

About this research paper

What this paper is about

Objective Investigate a rapid、accurate method of scintillation and non scintillation liquid on counting the radioactivity of 32 P. Methods According to the theory of Cerenkov radiation, different counting medium and condition on 32 P were studied. Results ① In different counting medium, the counting efficiency of non scintillation liquid in water, air and filter paper were 84%,67% and 60% of the scintillation liquid efficiency respectively.② Different vials: The plastic vials dealed with scintillation liquid had the highest counting efficiency, while the ordinary plastic and glass vials were 69% and 50% respectly. ③ The volume of samples (from 30 uL to 10 mL): the counting results of the samples of defferent volume were not significant change (P0.05). Conclusion The “dry” counting of 32 P by plastic vials dealed with scintillation liquid can obtain the highest counting efficiency, and can be used repeatly.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective Investigate a rapid、accurate method of scintillation and non scintillation liquid on counting the radioactivity of 32 P. Methods According to the theory of Cerenkov radiation, different counting medium and condition on 32 P were studied. Results ① In different counting medium, the counting efficiency of non scintillation liquid in water, air and filter paper were 84%,67% and 60% of the scintillation liquid efficiency respectively.② Different vials: The plastic vials dealed with scintillation liquid had the highest counting efficiency, while the ordinary plastic and glass vials were 69% and 50% respectly. ③ The volume of samples (from 30 uL to 10 mL): the counting results of the samples of defferent volume were not significant change (P0.05). Conclusion The “dry” counting of 32 P by plastic vials dealed with scintillation liquid can obtain the highest counting efficiency, and can be used repeatly.

Key concepts: Liquid scintillation counting, Counting efficiency, Scintillation, Vial, Materials science, Scintillation counter, Carbon-14, Volume (thermodynamics)

Related papers

Back to paper searchBrowse research topicsOriginal source
The Investigation of Non scintillation Liquid Counting on ~(32)P — Research Paper | ScholarLens