2009Chinese Journal of Applied ChemistryRequires access

Determination of Hypoxanthine,Xanthine and Adenine Extracts in Four Animal Drugs by HPLC

Lin Wang

Open publisher page 0 citations

Abstract

Hypoxanthine,xanthine and adenine in some animal drug materials were determined by means of HPLC with methanol/water as the mobile phase and a UV detector.This process of sample preparation was improved and the conditions of HPLC were also optimized.The detection limits of hypoxanthine,xanthine and adenine were 0.012×10-6,0.041×10-6,0.042×10-6 g/mL,respectively.The intra-day precisions(RSD) of hypoxanthine,xanthine and adenine were less than 4.1%,7.3% and 4.5%,respectively.The inter-day precisions(RSD) of hypoxanthine,xanthine and adenine were less than 5.8%,2.9% and 3.1%,respectively.The recovery rates of the four samples with added specimen were in a range of 94% to 107%.

About this research paper

What this paper is about

Hypoxanthine,xanthine and adenine in some animal drug materials were determined by means of HPLC with methanol/water as the mobile phase and a UV detector.This process of sample preparation was improved and the conditions of HPLC were also optimized.The detection limits of hypoxanthine,xanthine and adenine were 0.012×10-6,0.041×10-6,0.042×10-6 g/mL,respectively.The intra-day precisions(RSD) of hypoxanthine,xanthine and adenine were less than 4.1%,7.3% and 4.5%,respectively.The inter-day precisions(RSD) of hypoxanthine,xanthine and adenine were less than 5.8%,2.9% and 3.1%,respectively.The recovery rates of the four samples with added specimen were in a range of 94% to 107%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hypoxanthine,xanthine and adenine in some animal drug materials were determined by means of HPLC with methanol/water as the mobile phase and a UV detector.This process of sample preparation was improved and the conditions of HPLC were also optimized.The detection limits of hypoxanthine,xanthine and adenine were 0.012×10-6,0.041×10-6,0.042×10-6 g/mL,respectively.The intra-day precisions(RSD) of hypoxanthine,xanthine and adenine were less than 4.1%,7.3% and 4.5%,respectively.The inter-day precisions(RSD) of hypoxanthine,xanthine and adenine were less than 5.8%,2.9% and 3.1%,respectively.The recovery rates of the four samples with added specimen were in a range of 94% to 107%.

Key concepts: Hypoxanthine, Xanthine, Chemistry, High-performance liquid chromatography, Chromatography, Detection limit, Xanthine oxidase, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Hypoxanthine,Xanthine and Adenine Extracts in Four Animal Drugs by HPLC — Research Paper | ScholarLens