2015•Tobacco Science & TechnologyRequires access

Determination of Major Phenolic Compounds Retained by Cigarette Filter with High Performance Liquid Chromatography

HU Niannia

Open publisher page 2 citations

Abstract

In order to accurately determine the major phenolic compounds(hydroquinol,resorcinol, catechol, phenol, p-cresol, m-cresol, o-cresol) retained by cigarette filters, a rapid and accurate high performance liquid chromatography(HPLC) method was developed by investigating sample pretreatment conditions, such as filter-slitting means, extraction solvent,extraction method, and extraction time. A comparative experiment on seven filter cigarette samples was performed with the developed method among six laboratories. The results showed that: 1) By slitting the filter longitudinally from the tobacco end to the mouth end, then subjecting it to ultrasonic extraction with 50 m L solution(1% acetic acid, 79% methanol and20% water, V/V) for 30 minutes at room temperature, the said phenolic compounds retained in the filter could be completely extracted. 2) Within the concentration of 0.04-4.00 μg/m L, the said phenolic compounds exhibited good linear relations with R2 0.999, the recoveries ranged from93.35% to 104.50% with relative standard deviations(RSDs) 7.3%. 3) The RSD of the six laboratories in resorcinol and phenol determination was less than 15%, in the other five phenolic compounds determination was less than 10%. This method is suitable for determining the said phenolic compounds in mainstream cigarette smoke retained by cigarette filter.

About this research paper

What this paper is about

In order to accurately determine the major phenolic compounds(hydroquinol,resorcinol, catechol, phenol, p-cresol, m-cresol, o-cresol) retained by cigarette filters, a rapid and accurate high performance liquid chromatography(HPLC) method was developed by investigating sample pretreatment conditions, such as filter-slitting means, extraction solvent,extraction method, and extraction time. A comparative experiment on seven filter cigarette samples was performed with the developed method among six laboratories. The results showed that: 1) By slitting the filter longitudinally from the tobacco end to the mouth end, then subjecting it to ultrasonic extraction with 50 m L solution(1% acetic acid, 79% methanol and20% water, V/V) for 30 minutes at room temperature, the said phenolic compounds retained in the filter could be completely extracted. 2) Within the concentration of 0.04-4.00 μg/m L, the said phenolic compounds exhibited good linear relations with R2 0.999, the recoveries ranged from93.35% to 104.50% with relative standard deviations(RSDs) 7.3%. 3) The RSD of the six laboratories in resorcinol and phenol determination was less than 15%, in the other five phenolic compounds determination was less than 10%. This method is suitable for determining the said phenolic compounds in mainstream cigarette smoke retained by cigarette filter.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to accurately determine the major phenolic compounds(hydroquinol,resorcinol, catechol, phenol, p-cresol, m-cresol, o-cresol) retained by cigarette filters, a rapid and accurate high performance liquid chromatography(HPLC) method was developed by investigating sample pretreatment conditions, such as filter-slitting means, extraction solvent,extraction method, and extraction time. A comparative experiment on seven filter cigarette samples was performed with the developed method among six laboratories. The results showed that: 1) By slitting the filter longitudinally from the tobacco end to the mouth end, then subjecting it to ultrasonic extraction with 50 m L solution(1% acetic acid, 79% methanol and20% water, V/V) for 30 minutes at room temperature, the said phenolic compounds retained in the filter could be completely extracted. 2) Within the concentration of 0.04-4.00 μg/m L, the said phenolic compounds exhibited good linear relations with R2 0.999, the recoveries ranged from93.35% to 104.50% with relative standard deviations(RSDs) 7.3%. 3) The RSD of the six laboratories in resorcinol and phenol determination was less than 15%, in the other five phenolic compounds determination was less than 10%. This method is suitable for determining the said phenolic compounds in mainstream cigarette smoke retained by cigarette filter.

Key concepts: Chromatography, Chemistry, Resorcinol, Phenol, Catechol, Extraction (chemistry), High-performance liquid chromatography, Acetic acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Major Phenolic Compounds Retained by Cigarette Filter with High Performance Liquid Chromatography — Research Paper | ScholarLens