2006Chinese journal of plastic surgeryRequires access

Individual 3-D image prototyping models for orbital reconstruction

Lin Li

Open publisher page 0 citations

Abstract

Objective To fabricate a rapid prototyping(RP) 3-D image models for individual reconstruction of orbital bony loss. Methods The skull was placed on a helical CT scanner table and the Frankfort plane was perpendicular to the table. The CT data was obtained by a Aquilion (TOSHIBA, Japan) with 1 mm thickness section in spiral mode. By adjusting of CT threshold value and pixels in order to stack the segmental defects, we obtained an approximate 3-dimension visual model of the scanned skull using MedGraphics software. An orbital RP model based on the dataset of the 3-dimension visual model was fabricated by RP machine. Both 3-dimension visual model and RP model were measured against the skull with several anatomic landmarks to examine the accuracy of the models, and the errors were analysed. Results Integrity precision rapid RP models of the orbital region were reconstructed. The anterior orbital rim, middle orbital section and posterior orbital section were all fabricated. Optic foramen, superior orbital fissure, infraorbital foramen ,inferior orbital fissure, lacrimal sac socket and naso-lacrimal duct were shown clearly. But some fine hole and slot, such as the anterior ethmoidal foramen, posterior ethmoidal foramen and zygomaticofrontal suture were not obviously seen. The mean difference between the 3-dimension visual model and the skull was 0.10±1.02mm. For the RP and dry skull, the mean difference was 0.22±1.04mm. There were no statistical differences between them. Conclusions Integrity precision orbital RP models were fabricated which fulfilled the requirements of the individual reconstruction with bony orbital pathologic changes. The keys to fabricate the precision orbital RP models included a closer cooperation between the surgeon and engineer, thin CT slice in 1mm thick and an appropriated threshold value. Better results for the orbital deformities should be achieved for the contour of orbital region or eye function.

About this research paper

What this paper is about

Objective To fabricate a rapid prototyping(RP) 3-D image models for individual reconstruction of orbital bony loss. Methods The skull was placed on a helical CT scanner table and the Frankfort plane was perpendicular to the table. The CT data was obtained by a Aquilion (TOSHIBA, Japan) with 1 mm thickness section in spiral mode. By adjusting of CT threshold value and pixels in order to stack the segmental defects, we obtained an approximate 3-dimension visual model of the scanned skull using MedGraphics software. An orbital RP model based on the dataset of the 3-dimension visual model was fabricated by RP machine. Both 3-dimension visual model and RP model were measured against the skull with several anatomic landmarks to examine the accuracy of the models, and the errors were analysed. Results Integrity precision rapid RP models of the orbital region were reconstructed. The anterior orbital rim, middle orbital section and posterior orbital section were all fabricated. Optic foramen, superior orbital fissure, infraorbital foramen ,inferior orbital fissure, lacrimal sac socket and naso-lacrimal duct were shown clearly. But some fine hole and slot, such as the anterior ethmoidal foramen, posterior ethmoidal foramen and zygomaticofrontal suture were not obviously seen. The mean difference between the 3-dimension visual model and the skull was 0.10±1.02mm. For the RP and dry skull, the mean difference was 0.22±1.04mm. There were no statistical differences between them. Conclusions Integrity precision orbital RP models were fabricated which fulfilled the requirements of the individual reconstruction with bony orbital pathologic changes. The keys to fabricate the precision orbital RP models included a closer cooperation between the surgeon and engineer, thin CT slice in 1mm thick and an appropriated threshold value. Better results for the orbital deformities should be achieved for the contour of orbital region or eye function.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To fabricate a rapid prototyping(RP) 3-D image models for individual reconstruction of orbital bony loss. Methods The skull was placed on a helical CT scanner table and the Frankfort plane was perpendicular to the table. The CT data was obtained by a Aquilion (TOSHIBA, Japan) with 1 mm thickness section in spiral mode. By adjusting of CT threshold value and pixels in order to stack the segmental defects, we obtained an approximate 3-dimension visual model of the scanned skull using MedGraphics software. An orbital RP model based on the dataset of the 3-dimension visual model was fabricated by RP machine. Both 3-dimension visual model and RP model were measured against the skull with several anatomic landmarks to examine the accuracy of the models, and the errors were analysed. Results Integrity precision rapid RP models of the orbital region were reconstructed. The anterior orbital rim, middle orbital section and posterior orbital section were all fabricated. Optic foramen, superior orbital fissure, infraorbital foramen ,inferior orbital fissure, lacrimal sac socket and naso-lacrimal duct were shown clearly. But some fine hole and slot, such as the anterior ethmoidal foramen, posterior ethmoidal foramen and zygomaticofrontal suture were not obviously seen. The mean difference between the 3-dimension visual model and the skull was 0.10±1.02mm. For the RP and dry skull, the mean difference was 0.22±1.04mm. There were no statistical differences between them. Conclusions Integrity precision orbital RP models were fabricated which fulfilled the requirements of the individual reconstruction with bony orbital pathologic changes. The keys to fabricate the precision orbital RP models included a closer cooperation between the surgeon and engineer, thin CT slice in 1mm thick and an appropriated threshold value. Better results for the orbital deformities should be achieved for the contour of orbital region or eye function.

Key concepts: Skull, Anatomy, Orbit (dynamics), Foramen, Orbital Fracture, Calipers, Coronal plane, Geology

Related papers

Back to paper searchBrowse research topicsOriginal source
Individual 3-D image prototyping models for orbital reconstruction — Research Paper | ScholarLens