2010AFRICAN JOURNAL OF BIOTECHNOLOGYOpen access

Research Paper Polyclonal antibodies production against Staphylococcus aureus protein A: ELISA technique optimization for milk quality control

Y Belkessam, M Benali, S Moulessehoul, D. von Harrach

Open full text 0 citations

Abstract

The main aim of this project is to produce polyclonal antibodies directed against the Staphylococcus aureus protein A and their use to appreciate bacteriological analysis of milk quality. In this context, an immunization produce was set up to test and detect in a batch of animals the convenient responder to the injected antigen. Furthermore, to optimize all parameters of retained ELISA test, a cross-table was conceived by using various concentrations of different reagents and has allowed selecting the optimal dilutions as follows: 1) 1/1000 for anti-Staphylococcus aureus protein A mouse antibodies and 1/2000 for anti-Staphylococcus aureus protein A rabbit antibodies. 2) 1/4000 for anti-Staphylococcus aureus treated by heat mouse antibodies and 1/500 for anti-Staphylococcus aureus protein A rabbit antibodies. 3) 1/2000 for anti-Staphylococcus aureus treated by NaClO mouse antibodies and 1/500 for anti-Staphylococcus aureus protein A rabbit antibodies. The application of optimized ELISA test to search and detect Staphylococcus aureus germs in different samples of milk has shown very satisfying results when compared to those obtained by bacteriological method. Indeed, the sensitiveness and the reproducibility, as well as the possibility to analyze a great number of samples in the same time at a reduced manner make the immunochemical method a best choice of test able to replace recent bacteriological methods.

About this research paper

What this paper is about

The main aim of this project is to produce polyclonal antibodies directed against the Staphylococcus aureus protein A and their use to appreciate bacteriological analysis of milk quality. In this context, an immunization produce was set up to test and detect in a batch of animals the convenient responder to the injected antigen. Furthermore, to optimize all parameters of retained ELISA test, a cross-table was conceived by using various concentrations of different reagents and has allowed selecting the optimal dilutions as follows: 1) 1/1000 for anti-Staphylococcus aureus protein A mouse antibodies and 1/2000 for anti-Staphylococcus aureus protein A rabbit antibodies. 2) 1/4000 for anti-Staphylococcus aureus treated by heat mouse antibodies and 1/500 for anti-Staphylococcus aureus protein A rabbit antibodies. 3) 1/2000 for anti-Staphylococcus aureus treated by NaClO mouse antibodies and 1/500 for anti-Staphylococcus aureus protein A rabbit antibodies. The application of optimized ELISA test to search and detect Staphylococcus aureus germs in different samples of milk has shown very satisfying results when compared to those obtained by bacteriological method. Indeed, the sensitiveness and the reproducibility, as well as the possibility to analyze a great number of samples in the same time at a reduced manner make the immunochemical method a best choice of test able to replace recent bacteriological methods.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The main aim of this project is to produce polyclonal antibodies directed against the Staphylococcus aureus protein A and their use to appreciate bacteriological analysis of milk quality. In this context, an immunization produce was set up to test and detect in a batch of animals the convenient responder to the injected antigen. Furthermore, to optimize all parameters of retained ELISA test, a cross-table was conceived by using various concentrations of different reagents and has allowed selecting the optimal dilutions as follows: 1) 1/1000 for anti-Staphylococcus aureus protein A mouse antibodies and 1/2000 for anti-Staphylococcus aureus protein A rabbit antibodies. 2) 1/4000 for anti-Staphylococcus aureus treated by heat mouse antibodies and 1/500 for anti-Staphylococcus aureus protein A rabbit antibodies. 3) 1/2000 for anti-Staphylococcus aureus treated by NaClO mouse antibodies and 1/500 for anti-Staphylococcus aureus protein A rabbit antibodies. The application of optimized ELISA test to search and detect Staphylococcus aureus germs in different samples of milk has shown very satisfying results when compared to those obtained by bacteriological method. Indeed, the sensitiveness and the reproducibility, as well as the possibility to analyze a great number of samples in the same time at a reduced manner make the immunochemical method a best choice of test able to replace recent bacteriological methods.

Key concepts: Staphylococcus aureus, Polyclonal antibodies, Protein A, Antibody, Microbiology, Staphylococcus, Context (archaeology), Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Research Paper Polyclonal antibodies production against Staphylococcus aureus protein A: ELISA technique optimization for milk quality control — Research Paper | ScholarLens