2013Acta Scientiarum Naturalium Universitatis SunyatseniRequires access

A pilot study of single-use endoscopy in screening acute gastrointestinal bleeding

Jae, Hee, Cho, Man, K W Kim, Sangheun, Lee, Yu, Jin, Ki, Jun, Han, Hyeon, Geun, Si Si, Duncan Young, Сонг

Open publisher page 0 citations

Abstract

AIM:To investigate the feasibility of a single-use endoscopy as an alternative procedure to nasogastric lavage in patients with acute gastrointestinal(GI) bleeding.METHODS:Patients who presented with hematemesis,melena or hematochezia were enrolled in this study.EG scan and conventional esophagogastroduodenoscopy(EGD) were subsequently performed.Active bleeding was defined as blood in the stomach,and inactive bleeding was defined as coffee ground clots and clear fluid in the stomach.The findings were recorded and compared.RESULTS:Between January and March,2011,13 patients that presented with hematemesis(n = 4),melena(n = 6),or bleeding from a previous nasogastric feeding tube(n = 3),were enrolled in this study.In 12 patients with upper GI bleeding,the EG scan device revealed that 7 patients had active bleeding and 5 patients had inactive bleeding,whereas conventional EGD revealed that 8 patients had active bleeding and 4 patients had inactive bleeding.The sensitivity and specificity of the EG scan device was 87.5% and 100% for active bleeding,with conventional EGD serving as a reference.No complication were reported during the EG scan procedures.CONCLUSION:The EG scan is a feasible device for screening acute upper GI bleeding.It may replace nasogastric lavage for the evaluation of acute upper GI bleeding.

About this research paper

What this paper is about

AIM:To investigate the feasibility of a single-use endoscopy as an alternative procedure to nasogastric lavage in patients with acute gastrointestinal(GI) bleeding.METHODS:Patients who presented with hematemesis,melena or hematochezia were enrolled in this study.EG scan and conventional esophagogastroduodenoscopy(EGD) were subsequently performed.Active bleeding was defined as blood in the stomach,and inactive bleeding was defined as coffee ground clots and clear fluid in the stomach.The findings were recorded and compared.RESULTS:Between January and March,2011,13 patients that presented with hematemesis(n = 4),melena(n = 6),or bleeding from a previous nasogastric feeding tube(n = 3),were enrolled in this study.In 12 patients with upper GI bleeding,the EG scan device revealed that 7 patients had active bleeding and 5 patients had inactive bleeding,whereas conventional EGD revealed that 8 patients had active bleeding and 4 patients had inactive bleeding.The sensitivity and specificity of the EG scan device was 87.5% and 100% for active bleeding,with conventional EGD serving as a reference.No complication were reported during the EG scan procedures.CONCLUSION:The EG scan is a feasible device for screening acute upper GI bleeding.It may replace nasogastric lavage for the evaluation of acute upper GI bleeding.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM:To investigate the feasibility of a single-use endoscopy as an alternative procedure to nasogastric lavage in patients with acute gastrointestinal(GI) bleeding.METHODS:Patients who presented with hematemesis,melena or hematochezia were enrolled in this study.EG scan and conventional esophagogastroduodenoscopy(EGD) were subsequently performed.Active bleeding was defined as blood in the stomach,and inactive bleeding was defined as coffee ground clots and clear fluid in the stomach.The findings were recorded and compared.RESULTS:Between January and March,2011,13 patients that presented with hematemesis(n = 4),melena(n = 6),or bleeding from a previous nasogastric feeding tube(n = 3),were enrolled in this study.In 12 patients with upper GI bleeding,the EG scan device revealed that 7 patients had active bleeding and 5 patients had inactive bleeding,whereas conventional EGD revealed that 8 patients had active bleeding and 4 patients had inactive bleeding.The sensitivity and specificity of the EG scan device was 87.5% and 100% for active bleeding,with conventional EGD serving as a reference.No complication were reported during the EG scan procedures.CONCLUSION:The EG scan is a feasible device for screening acute upper GI bleeding.It may replace nasogastric lavage for the evaluation of acute upper GI bleeding.

Key concepts: Melena, Medicine, Esophagogastroduodenoscopy, Hematochezia, Endoscopy, Gastrointestinal bleeding, GI bleeding, Upper gastrointestinal bleeding

Related papers

Back to paper searchBrowse research topicsOriginal source
A pilot study of single-use endoscopy in screening acute gastrointestinal bleeding — Research Paper | ScholarLens