Catheter Ablation of Accessory Pathways
Jonathan J. Langberg, Hugh Calkins, Steven J. Kalbfleisch
Abstract
Jonathan J. Langberg, Hugh Calkins, Steven J. Kalbfleisch
Abstract
Background. Animal studies have suggested that the temperature of the electrode-tissue interface during radiofrequency catheter ablation accurately predicts lesion size. The purpose of the current study was to evaluate the utility of continuous temperature monitoring during radiofrequency catheter ablation in patients with Wolff-Parkinson-White syndrome. Methods and Results. Twenty patients with manifest preexcitation were included in the study. The ablation catheter was positioned on the ventricular side of the mitral annulus for left-sided accessory pathways and on the atrial side of the tricuspid annulus for right-sided and septal accessory pathways. A thermistor imbedded in the distal electrode of the ablation catheter allowed continuous temperature monitoring during each energy application. To define the relation between power and temperature, radiofrequency current was applied several times at each site using outputs of 20, 30, 40, and 50 W. The accessory pathways were successfully ablated in each of the 20 patients. Because of marked variability in the efficiency of heating between sites, power output did not predict temperature. However, at any given site, there was a positive dose-response relation between power and temperature. Radiofrequency energy applications on the atrial side of the tricuspid annulus produced lower temperatures than did applications
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background. Animal studies have suggested that the temperature of the electrode-tissue interface during radiofrequency catheter ablation accurately predicts lesion size. The purpose of the current study was to evaluate the utility of continuous temperature monitoring during radiofrequency catheter ablation in patients with Wolff-Parkinson-White syndrome. Methods and Results. Twenty patients with manifest preexcitation were included in the study. The ablation catheter was positioned on the ventricular side of the mitral annulus for left-sided accessory pathways and on the atrial side of the tricuspid annulus for right-sided and septal accessory pathways. A thermistor imbedded in the distal electrode of the ablation catheter allowed continuous temperature monitoring during each energy application. To define the relation between power and temperature, radiofrequency current was applied several times at each site using outputs of 20, 30, 40, and 50 W. The accessory pathways were successfully ablated in each of the 20 patients. Because of marked variability in the efficiency of heating between sites, power output did not predict temperature. However, at any given site, there was a positive dose-response relation between power and temperature. Radiofrequency energy applications on the atrial side of the tricuspid annulus produced lower temperatures than did applications
Key concepts: Ablation, Accessory pathway, Catheter ablation, Catheter, Medicine, Radiofrequency ablation, Thermistor, Annulus (botany)