2000Zhonghua jiehe he huxi zazhiRequires access

Proportional assist ventilation: methodology therapeutics on COPD patients compared with pressure support ventilation

YE Qia

Open publisher page 0 citations

Abstract

Objective To establish the method for clinical use of proportional assist ventilation (PAV)and evaluate the effect on COPD patients.The main similarities and differences of PAV and pressure support ventilation (PSV) were described.Methods 10 ventilated patients of COPD were studied. The elastance and resistance were determined before PAV by both inspiratory-hold technique during a brief period of volume control ventilation and runaway technique . Either different assist lerels of PAV (% assist 80%, 60%, 40%,respectively) or PSV was selected randomly. Values of hemodynamics, blood gas and pulmonary mechanics were monitored. Patients' response was described also.Results Runaway technique was convenient and reliable.Among different assist percentage no significant difference was found on hemodynamics in stabilized COPD patients.PaO2 was in a good level. Either tidal volume or respiratory rate did not change in a consistent way as the level of assist was decreased. But peak inspiratory pressure was increasing significantly r = 0.928 (P 0.01 ) and patients' work of breath had the tendency to decrease (P 0.05). A significant difference of Borg Category Scale was observed between PAV and PSV [0.50(1 .50) ] vs [0.75(2.00)], (P 0.05). No significant difference of hemodynamics was found beteen the two modes. PaCO2 was significantly higher on PAV than on PSV,54(24) and 48(23) mm Hg, respectively (P 0.05). Peak inspiratory pressure on PAV (16 ±4) cm H2O was significantly lower than on PSV(21 ±3) cm H2O (P 0.05). Conclusions PAV is a feasible method of supporting ventilator-dependent patients that is well tolerated. It can improve breathing pattern and reduce inspiratory effort by decreasing work of breath. PAV can be implemented at much lower peak inspiratory pressure than PSV at the same condition of work of breath by patients. It can also apply proportional pressure support according to patients'ventilatory demand. System that operates according to the theory of PAV is no easy to implement. How to measure elastance and resistance is still a question during the development of PAV.

About this research paper

What this paper is about

Objective To establish the method for clinical use of proportional assist ventilation (PAV)and evaluate the effect on COPD patients.The main similarities and differences of PAV and pressure support ventilation (PSV) were described.Methods 10 ventilated patients of COPD were studied. The elastance and resistance were determined before PAV by both inspiratory-hold technique during a brief period of volume control ventilation and runaway technique . Either different assist lerels of PAV (% assist 80%, 60%, 40%,respectively) or PSV was selected randomly. Values of hemodynamics, blood gas and pulmonary mechanics were monitored. Patients' response was described also.Results Runaway technique was convenient and reliable.Among different assist percentage no significant difference was found on hemodynamics in stabilized COPD patients.PaO2 was in a good level. Either tidal volume or respiratory rate did not change in a consistent way as the level of assist was decreased. But peak inspiratory pressure was increasing significantly r = 0.928 (P 0.01 ) and patients' work of breath had the tendency to decrease (P 0.05). A significant difference of Borg Category Scale was observed between PAV and PSV [0.50(1 .50) ] vs [0.75(2.00)], (P 0.05). No significant difference of hemodynamics was found beteen the two modes. PaCO2 was significantly higher on PAV than on PSV,54(24) and 48(23) mm Hg, respectively (P 0.05). Peak inspiratory pressure on PAV (16 ±4) cm H2O was significantly lower than on PSV(21 ±3) cm H2O (P 0.05). Conclusions PAV is a feasible method of supporting ventilator-dependent patients that is well tolerated. It can improve breathing pattern and reduce inspiratory effort by decreasing work of breath. PAV can be implemented at much lower peak inspiratory pressure than PSV at the same condition of work of breath by patients. It can also apply proportional pressure support according to patients'ventilatory demand. System that operates according to the theory of PAV is no easy to implement. How to measure elastance and resistance is still a question during the development of PAV.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish the method for clinical use of proportional assist ventilation (PAV)and evaluate the effect on COPD patients.The main similarities and differences of PAV and pressure support ventilation (PSV) were described.Methods 10 ventilated patients of COPD were studied. The elastance and resistance were determined before PAV by both inspiratory-hold technique during a brief period of volume control ventilation and runaway technique . Either different assist lerels of PAV (% assist 80%, 60%, 40%,respectively) or PSV was selected randomly. Values of hemodynamics, blood gas and pulmonary mechanics were monitored. Patients' response was described also.Results Runaway technique was convenient and reliable.Among different assist percentage no significant difference was found on hemodynamics in stabilized COPD patients.PaO2 was in a good level. Either tidal volume or respiratory rate did not change in a consistent way as the level of assist was decreased. But peak inspiratory pressure was increasing significantly r = 0.928 (P 0.01 ) and patients' work of breath had the tendency to decrease (P 0.05). A significant difference of Borg Category Scale was observed between PAV and PSV [0.50(1 .50) ] vs [0.75(2.00)], (P 0.05). No significant difference of hemodynamics was found beteen the two modes. PaCO2 was significantly higher on PAV than on PSV,54(24) and 48(23) mm Hg, respectively (P 0.05). Peak inspiratory pressure on PAV (16 ±4) cm H2O was significantly lower than on PSV(21 ±3) cm H2O (P 0.05). Conclusions PAV is a feasible method of supporting ventilator-dependent patients that is well tolerated. It can improve breathing pattern and reduce inspiratory effort by decreasing work of breath. PAV can be implemented at much lower peak inspiratory pressure than PSV at the same condition of work of breath by patients. It can also apply proportional pressure support according to patients'ventilatory demand. System that operates according to the theory of PAV is no easy to implement. How to measure elastance and resistance is still a question during the development of PAV.

Key concepts: Pressure support ventilation, Medicine, Ventilation (architecture), COPD, Peak inspiratory pressure, Tidal volume, Hemodynamics, Significant difference

Related papers

Back to paper searchBrowse research topicsOriginal source
Proportional assist ventilation: methodology therapeutics on COPD patients compared with pressure support ventilation — Research Paper | ScholarLens