2021•PubMedRequires access

[Comparison of clinical efficacy of two different pin arrangements for external fixation of femoral neck fracture].

Donghui Zhang, Yang Zhang, Liying Liu, Jin‐Xing Wang, Xi-Qing Hu, Guosheng Zhao, Xiao-Hu Wu, Hong-Ru Jiang

Open publisher page 0 citations

Abstract

OBJECTIVE: To retrospectively analyze the clinical efficacy of external fixation in the treatment of femoral neck fracture with two different pin layout. METHODS: From April 2000 to April 2018, 140 cases of femoral neck fracture were treated with closed reduction and percutaneous pin external fixation, among them 121 cases were followed up for more than 1 year, including 31 cases in traditional group, 12 males and 19 females, aged 45 to 74(65.4±8.4) years;90 cases in modified group, 39 males and 51 females, aged 12 to 75 (64.5±7.8) years. In traditional group, the first needle was put on the femoral talus, the second and third needles were put under the tension line, and the three needles were not on the same line in the lateral phase; in modified group, the first needle was drilled into the lateralcortex of the femur, obliquely penetrating the distal and proximal end of the femoral talus fracture, and the other two needles were drilled into the medial cortex of the femoral neck and the femoral talus, respectively. The operation time, hospital stay, postoperative ambulation time, femoral neck shortening rate, fracture healing time, fracture healing rate and femoral head necrosis rate of the two groups were observed and compared. Harris hip function score was used one year after operation. RESULTS: <0.05). CONCLUSION: Compared with the traditional group, the modified group has the advantages of lower femoral neck shortening rate, shorter fracture healing time, higher fracture healing rate and higher Harris hip function score.

About this research paper

What this paper is about

OBJECTIVE: To retrospectively analyze the clinical efficacy of external fixation in the treatment of femoral neck fracture with two different pin layout. METHODS: From April 2000 to April 2018, 140 cases of femoral neck fracture were treated with closed reduction and percutaneous pin external fixation, among them 121 cases were followed up for more than 1 year, including 31 cases in traditional group, 12 males and 19 females, aged 45 to 74(65.4±8.4) years;90 cases in modified group, 39 males and 51 females, aged 12 to 75 (64.5±7.8) years. In traditional group, the first needle was put on the femoral talus, the second and third needles were put under the tension line, and the three needles were not on the same line in the lateral phase; in modified group, the first needle was drilled into the lateralcortex of the femur, obliquely penetrating the distal and proximal end of the femoral talus fracture, and the other two needles were drilled into the medial cortex of the femoral neck and the femoral talus, respectively. The operation time, hospital stay, postoperative ambulation time, femoral neck shortening rate, fracture healing time, fracture healing rate and femoral head necrosis rate of the two groups were observed and compared. Harris hip function score was used one year after operation. RESULTS: <0.05). CONCLUSION: Compared with the traditional group, the modified group has the advantages of lower femoral neck shortening rate, shorter fracture healing time, higher fracture healing rate and higher Harris hip function score.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To retrospectively analyze the clinical efficacy of external fixation in the treatment of femoral neck fracture with two different pin layout. METHODS: From April 2000 to April 2018, 140 cases of femoral neck fracture were treated with closed reduction and percutaneous pin external fixation, among them 121 cases were followed up for more than 1 year, including 31 cases in traditional group, 12 males and 19 females, aged 45 to 74(65.4±8.4) years;90 cases in modified group, 39 males and 51 females, aged 12 to 75 (64.5±7.8) years. In traditional group, the first needle was put on the femoral talus, the second and third needles were put under the tension line, and the three needles were not on the same line in the lateral phase; in modified group, the first needle was drilled into the lateralcortex of the femur, obliquely penetrating the distal and proximal end of the femoral talus fracture, and the other two needles were drilled into the medial cortex of the femoral neck and the femoral talus, respectively. The operation time, hospital stay, postoperative ambulation time, femoral neck shortening rate, fracture healing time, fracture healing rate and femoral head necrosis rate of the two groups were observed and compared. Harris hip function score was used one year after operation. RESULTS: <0.05). CONCLUSION: Compared with the traditional group, the modified group has the advantages of lower femoral neck shortening rate, shorter fracture healing time, higher fracture healing rate and higher Harris hip function score.

Key concepts: Medicine, Femoral neck, Surgery, Femoral head, Fixation (population genetics), Percutaneous, Femur, Bone healing

Related papers

Back to paper searchBrowse research topicsOriginal source
[Comparison of clinical efficacy of two different pin arrangements for external fixation of femoral neck fracture]. — Research Paper | ScholarLens