2006Unpublished venueRequires access

Convenient Method of Relative Calibration of the Neutron Source Emission Rate Between Different Source Types

Hideki Harano, Tetsuro Matsumoto, Tetsuya Shimoyama, Yasushi Sato, Akira Uritani, Y. Hino, K. Kudo, Taichi MICHIKAWA

Open publisher page 0 citations

Abstract

Neutron source emission rates are determined by absolute or relative measurement. The relative measurement is performed by comparing between a sample source and a calibrated reference source of the same type. In this calibration, the energy spectra of the sample and reference sources should be identical, since normally there exists energy dependence in the response of neutron detectors. We propose a method of relative calibration of the neutron source emission rate between different source types and spectra. In the present method, a sample source or a calibrated reference source is located at the center of a graphite pile and thermal neutron flux at a special position is monitored and compared. We performed gold foil activation measurements at the NMIJ/AIST graphite pile and revealed that the thermal neutron flux at that position per unit source emission rate is independent on the types of neutron sources. The details of the physical mechanism were examined by calculating the spectral fluence of the neutrons thermalized inside the graphite pile using the MCNP4C code. We demonstrated this method using Am-Be, Ra(alpha)-Be, Cf, Pu-Be neutron sources and obtained the successful results which agreed within 1%

About this research paper

What this paper is about

Neutron source emission rates are determined by absolute or relative measurement. The relative measurement is performed by comparing between a sample source and a calibrated reference source of the same type. In this calibration, the energy spectra of the sample and reference sources should be identical, since normally there exists energy dependence in the response of neutron detectors. We propose a method of relative calibration of the neutron source emission rate between different source types and spectra. In the present method, a sample source or a calibrated reference source is located at the center of a graphite pile and thermal neutron flux at a special position is monitored and compared. We performed gold foil activation measurements at the NMIJ/AIST graphite pile and revealed that the thermal neutron flux at that position per unit source emission rate is independent on the types of neutron sources. The details of the physical mechanism were examined by calculating the spectral fluence of the neutrons thermalized inside the graphite pile using the MCNP4C code. We demonstrated this method using Am-Be, Ra(alpha)-Be, Cf, Pu-Be neutron sources and obtained the successful results which agreed within 1%

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Neutron source emission rates are determined by absolute or relative measurement. The relative measurement is performed by comparing between a sample source and a calibrated reference source of the same type. In this calibration, the energy spectra of the sample and reference sources should be identical, since normally there exists energy dependence in the response of neutron detectors. We propose a method of relative calibration of the neutron source emission rate between different source types and spectra. In the present method, a sample source or a calibrated reference source is located at the center of a graphite pile and thermal neutron flux at a special position is monitored and compared. We performed gold foil activation measurements at the NMIJ/AIST graphite pile and revealed that the thermal neutron flux at that position per unit source emission rate is independent on the types of neutron sources. The details of the physical mechanism were examined by calculating the spectral fluence of the neutrons thermalized inside the graphite pile using the MCNP4C code. We demonstrated this method using Am-Be, Ra(alpha)-Be, Cf, Pu-Be neutron sources and obtained the successful results which agreed within 1%

Key concepts: Neutron source, Neutron flux, Calibration, Neutron, Neutron temperature, Bonner sphere, Graphite, Neutron detection

Related papers

Back to paper searchBrowse research topicsOriginal source
Convenient Method of Relative Calibration of the Neutron Source Emission Rate Between Different Source Types — Research Paper | ScholarLens