2002•Hydrometallurgy of ChinaRequires access

Determination of Uranium and Molybdenum in Separation Process of Uranium and Molybdenum (I):Determination of Uranium

Lu Ping Shi

Open publisher page 0 citations

Abstract

simple and rapid methods for determination of uranium in uranmolybdate,leaching residue,leaching solution,ion exchange resins and uranium chemical concentrates during separation of uranium and molybdenum have been studied The samples of ore and leaching residue are fused with mixed ammonium salt,the resin samples are roasted at high temperature The fused sample is dissolved in phosphoric acid In 60% phosphoric acid medium,uranium(Ⅵ) is reduced to uranium(Ⅳ) by ferrous In 40% phosphoric acid and in the presence of ammonium salt,the excess ferrous is oxidized with sodium nitrite,and excess sodium nitrite is destroyed with urea so as to interference of molybdenum can be eliminated The uranium can be determined by ammonium vanadate volumetric procedure,taking sodium diphenylaminesulfonate and phenyl o amidocarbonic acid as indicators Molybdenum in the samples of high content molybdenum can be separated as molybdenum acid precipitate The uranium products (uranium chemical concentrates)is dissolved with a small amount of hydrochloric acid,then the uranium is titrated directly using ammonium vanadate volumetric procedure The methods are simple and rapid and can be used to determine uranium in various samples The precision of analysis is over ± 10% and recovery rate is 98%~105%.The results are satisfactory

About this research paper

What this paper is about

simple and rapid methods for determination of uranium in uranmolybdate,leaching residue,leaching solution,ion exchange resins and uranium chemical concentrates during separation of uranium and molybdenum have been studied The samples of ore and leaching residue are fused with mixed ammonium salt,the resin samples are roasted at high temperature The fused sample is dissolved in phosphoric acid In 60% phosphoric acid medium,uranium(Ⅵ) is reduced to uranium(Ⅳ) by ferrous In 40% phosphoric acid and in the presence of ammonium salt,the excess ferrous is oxidized with sodium nitrite,and excess sodium nitrite is destroyed with urea so as to interference of molybdenum can be eliminated The uranium can be determined by ammonium vanadate volumetric procedure,taking sodium diphenylaminesulfonate and phenyl o amidocarbonic acid as indicators Molybdenum in the samples of high content molybdenum can be separated as molybdenum acid precipitate The uranium products (uranium chemical concentrates)is dissolved with a small amount of hydrochloric acid,then the uranium is titrated directly using ammonium vanadate volumetric procedure The methods are simple and rapid and can be used to determine uranium in various samples The precision of analysis is over ± 10% and recovery rate is 98%~105%.The results are satisfactory

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

simple and rapid methods for determination of uranium in uranmolybdate,leaching residue,leaching solution,ion exchange resins and uranium chemical concentrates during separation of uranium and molybdenum have been studied The samples of ore and leaching residue are fused with mixed ammonium salt,the resin samples are roasted at high temperature The fused sample is dissolved in phosphoric acid In 60% phosphoric acid medium,uranium(Ⅵ) is reduced to uranium(Ⅳ) by ferrous In 40% phosphoric acid and in the presence of ammonium salt,the excess ferrous is oxidized with sodium nitrite,and excess sodium nitrite is destroyed with urea so as to interference of molybdenum can be eliminated The uranium can be determined by ammonium vanadate volumetric procedure,taking sodium diphenylaminesulfonate and phenyl o amidocarbonic acid as indicators Molybdenum in the samples of high content molybdenum can be separated as molybdenum acid precipitate The uranium products (uranium chemical concentrates)is dissolved with a small amount of hydrochloric acid,then the uranium is titrated directly using ammonium vanadate volumetric procedure The methods are simple and rapid and can be used to determine uranium in various samples The precision of analysis is over ± 10% and recovery rate is 98%~105%.The results are satisfactory

Key concepts: Uranium, Chemistry, Molybdenum, Phosphoric acid, Leaching (pedology), Inorganic chemistry, Hydrochloric acid, Ferrous

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Uranium and Molybdenum in Separation Process of Uranium and Molybdenum (I):Determination of Uranium — Research Paper | ScholarLens