2011Chinese Journal of Reparative and Reconstructive SurgeryRequires access

TREATMENT OF DISPLACED RADIAL HEAD FRACTURES WITH INTERNAL FIXATION

Yanmin Li

Open publisher page 0 citations

Abstract

Objective To analyse the procedure and effectiveness of internal fixation in treatment of displaced radial head fractures.Methods Between August 2005 and May 2009,35 patients with displaced radial head fractures underwent open reduction and internal fixation with SmartNail and/or AO mini-plates.There were 28 males and 7 females with an average age of 28.4 years(range,17-48 years).The injury mechanism included traffic accident in 16 patients,falling in 13,and falling from height in 6.According to Mason classification,21 fractures were rated as type II,9 as type III,and 5 as type IV.All fracturs were closed fractures.Six cases complicated by radial neck fractures,1 case by olecranon fracture,3 by posterior dislocations of the elbow,1 by posterior dislocation of the elbow and coronoid process fracture,and 3 by medial collateral ligament injuries.The time from injury to operation was 3 to 7 days.Results Except 1 patient whose incision healed by second intention,healing of incision by first intention was achieved in the other patients.All patients were followed up 12-25 months with an average of 17 months.The average fracture healing time was 10.2 weeks(range,8-16 weeks).At last follow-up,the average flexion and extension of the elbow was 119°(range,95-145°).The average arc of forearm rotation was 126°(range,90-175°).According to elbow functional evaluation criteria by Broberg and Morrey,the results were excellent in 18 cases,good in 13,and fair in 4;the excellent and good rate was 88.6%.Conclusion In treatment of displaced radial head fractures,open reduction and internal fixation can be performed with SmartNail and/or AO mini-plates based on different fracture types and the short-term effectiveness is satisfactory.

About this research paper

What this paper is about

Objective To analyse the procedure and effectiveness of internal fixation in treatment of displaced radial head fractures.Methods Between August 2005 and May 2009,35 patients with displaced radial head fractures underwent open reduction and internal fixation with SmartNail and/or AO mini-plates.There were 28 males and 7 females with an average age of 28.4 years(range,17-48 years).The injury mechanism included traffic accident in 16 patients,falling in 13,and falling from height in 6.According to Mason classification,21 fractures were rated as type II,9 as type III,and 5 as type IV.All fracturs were closed fractures.Six cases complicated by radial neck fractures,1 case by olecranon fracture,3 by posterior dislocations of the elbow,1 by posterior dislocation of the elbow and coronoid process fracture,and 3 by medial collateral ligament injuries.The time from injury to operation was 3 to 7 days.Results Except 1 patient whose incision healed by second intention,healing of incision by first intention was achieved in the other patients.All patients were followed up 12-25 months with an average of 17 months.The average fracture healing time was 10.2 weeks(range,8-16 weeks).At last follow-up,the average flexion and extension of the elbow was 119°(range,95-145°).The average arc of forearm rotation was 126°(range,90-175°).According to elbow functional evaluation criteria by Broberg and Morrey,the results were excellent in 18 cases,good in 13,and fair in 4;the excellent and good rate was 88.6%.Conclusion In treatment of displaced radial head fractures,open reduction and internal fixation can be performed with SmartNail and/or AO mini-plates based on different fracture types and the short-term effectiveness is satisfactory.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To analyse the procedure and effectiveness of internal fixation in treatment of displaced radial head fractures.Methods Between August 2005 and May 2009,35 patients with displaced radial head fractures underwent open reduction and internal fixation with SmartNail and/or AO mini-plates.There were 28 males and 7 females with an average age of 28.4 years(range,17-48 years).The injury mechanism included traffic accident in 16 patients,falling in 13,and falling from height in 6.According to Mason classification,21 fractures were rated as type II,9 as type III,and 5 as type IV.All fracturs were closed fractures.Six cases complicated by radial neck fractures,1 case by olecranon fracture,3 by posterior dislocations of the elbow,1 by posterior dislocation of the elbow and coronoid process fracture,and 3 by medial collateral ligament injuries.The time from injury to operation was 3 to 7 days.Results Except 1 patient whose incision healed by second intention,healing of incision by first intention was achieved in the other patients.All patients were followed up 12-25 months with an average of 17 months.The average fracture healing time was 10.2 weeks(range,8-16 weeks).At last follow-up,the average flexion and extension of the elbow was 119°(range,95-145°).The average arc of forearm rotation was 126°(range,90-175°).According to elbow functional evaluation criteria by Broberg and Morrey,the results were excellent in 18 cases,good in 13,and fair in 4;the excellent and good rate was 88.6%.Conclusion In treatment of displaced radial head fractures,open reduction and internal fixation can be performed with SmartNail and/or AO mini-plates based on different fracture types and the short-term effectiveness is satisfactory.