CATALYTIC KINETIC SPECTROPHOTOMETRIC DETERMINATION OF TRACE COPPER WITH COPPER(II)-p-ACETYLCHLOROPHOSPHONAZO-HYDROGEN PEROXIDE SYSTEM
Zhai Qingzhou
Abstract
Zhai Qingzhou
Abstract
Copper(II) catalyzes the oxidation of p-acetylchlorophosphonazo(CPA pA) by hydrogen peroxide in 0.10 M phosphoric acid. A novel catalytic kinetic-spectrophotometric method is proposed for the determination of copper based on this principle. Copper(II) can be determined spectrophotometrically by measuring the decrease in the absorbance of CPA pA at the wavelength of 554 nm using the fixed-time method. The optimum reaction conditions are as follows: H 3PO 4 (1.00 M) 1.0 mL, CPA pA (2.19 × 10 -4 M) 1.5 mL, H 2O2 (4.30 × 10 -2 M) 1.2 mL, reaction temperature 100 o C and reaction time 13 min. The linear range for the determination of copper(II) is 0.020-0.30 µg/mL. The limit of detection is 10.94 ng/mL. The method was satisfactorily used to determine copper in tomato and cucumber samples. The relative standard deviation of thirteen replicate determinations was 1.20-1.34% and the recovery of the method was 99.5-103.9%.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Copper(II) catalyzes the oxidation of p-acetylchlorophosphonazo(CPA pA) by hydrogen peroxide in 0.10 M phosphoric acid. A novel catalytic kinetic-spectrophotometric method is proposed for the determination of copper based on this principle. Copper(II) can be determined spectrophotometrically by measuring the decrease in the absorbance of CPA pA at the wavelength of 554 nm using the fixed-time method. The optimum reaction conditions are as follows: H 3PO 4 (1.00 M) 1.0 mL, CPA pA (2.19 × 10 -4 M) 1.5 mL, H 2O2 (4.30 × 10 -2 M) 1.2 mL, reaction temperature 100 o C and reaction time 13 min. The linear range for the determination of copper(II) is 0.020-0.30 µg/mL. The limit of detection is 10.94 ng/mL. The method was satisfactorily used to determine copper in tomato and cucumber samples. The relative standard deviation of thirteen replicate determinations was 1.20-1.34% and the recovery of the method was 99.5-103.9%.
Key concepts: Chemistry, Copper, Hydrogen peroxide, Absorbance, Detection limit, Catalysis, Phosphoric acid, Spectrophotometry