1984Circulation ResearchRequires access

Development of collateral function with repetitive coronary occlusion in a canine model reduces myocardial reactive hyperemia in the absence of significant coronary stenosis.

HYamamoto, HTomoike, HShimokawa, SNabeyama, MNakamura

Open publisher page 0 citations

Abstract

The present study was designed to elucidate the role of collateral development, per se, on reactive hyperemia without persistent coronary stenosis in instrumented conscious dogs. Functional states of coronary collaterals were augmented by repetitive 2 minutes of coronary occlusion every 30 minutes for 2-9 days. Regional shortening measured sonomicrometrically recovered from -1.2 +/- 6.5% of the preocclusive state at the end of the first coronary occlusion to 100.5 +/- 1.2% (n = 8, P less than 0.01) after repeated coronary occlusions. Before and after collateral development, transient coronary occlusions of 5, 10, 20, 30, 60, 90, and 120 seconds were randomly performed. The degree of regional dysfunction and the following reactive hyperemic response were measured. Up to 20 seconds of coronary occlusion, the flow ratio and duration of coronary reactive hyperemia increased similarly, both before and after collateral development. However, when the duration of coronary occlusion was over 30 seconds, flow ratio...

About this research paper

What this paper is about

The present study was designed to elucidate the role of collateral development, per se, on reactive hyperemia without persistent coronary stenosis in instrumented conscious dogs. Functional states of coronary collaterals were augmented by repetitive 2 minutes of coronary occlusion every 30 minutes for 2-9 days. Regional shortening measured sonomicrometrically recovered from -1.2 +/- 6.5% of the preocclusive state at the end of the first coronary occlusion to 100.5 +/- 1.2% (n = 8, P less than 0.01) after repeated coronary occlusions. Before and after collateral development, transient coronary occlusions of 5, 10, 20, 30, 60, 90, and 120 seconds were randomly performed. The degree of regional dysfunction and the following reactive hyperemic response were measured. Up to 20 seconds of coronary occlusion, the flow ratio and duration of coronary reactive hyperemia increased similarly, both before and after collateral development. However, when the duration of coronary occlusion was over 30 seconds, flow ratio...

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The present study was designed to elucidate the role of collateral development, per se, on reactive hyperemia without persistent coronary stenosis in instrumented conscious dogs. Functional states of coronary collaterals were augmented by repetitive 2 minutes of coronary occlusion every 30 minutes for 2-9 days. Regional shortening measured sonomicrometrically recovered from -1.2 +/- 6.5% of the preocclusive state at the end of the first coronary occlusion to 100.5 +/- 1.2% (n = 8, P less than 0.01) after repeated coronary occlusions. Before and after collateral development, transient coronary occlusions of 5, 10, 20, 30, 60, 90, and 120 seconds were randomly performed. The degree of regional dysfunction and the following reactive hyperemic response were measured. Up to 20 seconds of coronary occlusion, the flow ratio and duration of coronary reactive hyperemia increased similarly, both before and after collateral development. However, when the duration of coronary occlusion was over 30 seconds, flow ratio...

Key concepts: Reactive hyperemia, Coronary occlusion, Cardiology, Medicine, Internal medicine, Occlusion, Collateral circulation, Stenosis

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of collateral function with repetitive coronary occlusion in a canine model reduces myocardial reactive hyperemia in the absence of significant coronary stenosis. — Research Paper | ScholarLens