Electrogram criteria for identification of appropriate target sites for radiofrequency catheter ablation of accessory atrioventricular connections.
HCalkins, Y NKim, SSchmaltz, JSousa, Rel-Atassi, ALeon, AKadish, J JLangberg, FMorady
Abstract
HCalkins, Y NKim, SSchmaltz, JSousa, Rel-Atassi, ALeon, AKadish, J JLangberg, FMorady
Abstract
BACKGROUNDCatheter ablation of accessory atrioventricular (AV) connections using radiofrequency current has been demonstrated to be effective in the majority of patients with the Wolff-Parkinson-White syndrome or paroxysmal supraventricular tachycardia involving a concealed accessory AV connection. However, electrogram criteria have not been established to guide attempts at radiofrequency catheter ablation.METHODS AND RESULTSThe characteristics of local electrograms recorded at successful and unsuccessful sites of radiofrequency catheter ablation were determined in 132 patients. Electrograms recorded at a total of 438 sites were analyzed: 338 recorded during ablation of 90 manifest accessory AV connections and 100 recorded during ablation of 44 concealed accessory AV connections. During ablation of manifest accessory AV connections, the independent predictors of outcome were electrogram stability (p less than 0.001), the interval between activation of the ventricular electrogram and onset of the QRS compl...
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUNDCatheter ablation of accessory atrioventricular (AV) connections using radiofrequency current has been demonstrated to be effective in the majority of patients with the Wolff-Parkinson-White syndrome or paroxysmal supraventricular tachycardia involving a concealed accessory AV connection. However, electrogram criteria have not been established to guide attempts at radiofrequency catheter ablation.METHODS AND RESULTSThe characteristics of local electrograms recorded at successful and unsuccessful sites of radiofrequency catheter ablation were determined in 132 patients. Electrograms recorded at a total of 438 sites were analyzed: 338 recorded during ablation of 90 manifest accessory AV connections and 100 recorded during ablation of 44 concealed accessory AV connections. During ablation of manifest accessory AV connections, the independent predictors of outcome were electrogram stability (p less than 0.001), the interval between activation of the ventricular electrogram and onset of the QRS compl...
Key concepts: Medicine, Ablation, Accessory pathway, Radiofrequency catheter ablation, Cardiology, Internal medicine, Radiofrequency ablation, Catheter ablation