2008•CHINESE JOURNAL OF ANALYTICAL CHEMISTRY (CHINESE VERSION)Requires access

Application of 2-(11H-benzo[a]carbazol-11-yl) Ethyl Carbonochloridate as a Pro-column Derivatization Reagent of Amino Acid by High Performance Liquid Chromatography with Fluorescence Detection

Zhao We

Open publisher page 0 citations

Abstract

On a reversed phase Hypersil BDS C18(200 mm×4.6 mm,5 μm)column,20 amino acids,which were derivatized using 2-(11H-benzo[a]carbazol-11-yl)ethyl carbonochloridate(BCEC-Cl)as pre-column derivatization reagent,were separated in conjunction with a gradient elution.Optimum derivatization was obtained by reacting of amino acids with BCEC-Cl at room temperature for 5 min in the presence of sodium borate catalyst in acetonitrile solvent.The fluorescence excitation and emission wavelengths were 279 nm and 380 nm respectively.The identification of amino acid derivatives from hydrolyzed bovine serum albumin and bee pollen was carried out by post-column mass spectrometry with electrospray ion source in positive ion mode.Linear correlation coefficients of the amino acid derivatives were 0.9990,and detection limits(at signal to noise of 3∶1)were 1.49-19.74 fmol for the labeled amino acids.

About this research paper

What this paper is about

On a reversed phase Hypersil BDS C18(200 mm×4.6 mm,5 μm)column,20 amino acids,which were derivatized using 2-(11H-benzo[a]carbazol-11-yl)ethyl carbonochloridate(BCEC-Cl)as pre-column derivatization reagent,were separated in conjunction with a gradient elution.Optimum derivatization was obtained by reacting of amino acids with BCEC-Cl at room temperature for 5 min in the presence of sodium borate catalyst in acetonitrile solvent.The fluorescence excitation and emission wavelengths were 279 nm and 380 nm respectively.The identification of amino acid derivatives from hydrolyzed bovine serum albumin and bee pollen was carried out by post-column mass spectrometry with electrospray ion source in positive ion mode.Linear correlation coefficients of the amino acid derivatives were 0.9990,and detection limits(at signal to noise of 3∶1)were 1.49-19.74 fmol for the labeled amino acids.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

On a reversed phase Hypersil BDS C18(200 mm×4.6 mm,5 μm)column,20 amino acids,which were derivatized using 2-(11H-benzo[a]carbazol-11-yl)ethyl carbonochloridate(BCEC-Cl)as pre-column derivatization reagent,were separated in conjunction with a gradient elution.Optimum derivatization was obtained by reacting of amino acids with BCEC-Cl at room temperature for 5 min in the presence of sodium borate catalyst in acetonitrile solvent.The fluorescence excitation and emission wavelengths were 279 nm and 380 nm respectively.The identification of amino acid derivatives from hydrolyzed bovine serum albumin and bee pollen was carried out by post-column mass spectrometry with electrospray ion source in positive ion mode.Linear correlation coefficients of the amino acid derivatives were 0.9990,and detection limits(at signal to noise of 3∶1)were 1.49-19.74 fmol for the labeled amino acids.

Key concepts: Chemistry, Derivatization, Chromatography, Reagent, Acetonitrile, Detection limit, Amino acid, Electrospray

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of 2-(11H-benzo[a]carbazol-11-yl) Ethyl Carbonochloridate as a Pro-column Derivatization Reagent of Amino Acid by High Performance Liquid Chromatography with Fluorescence Detection — Research Paper | ScholarLens