2021Acta Veterinaria BrasilicaOpen access

Gaining body temperature in horses: mercury, digital and infrared thermometer in different locations

Ana Paula da Costa Rodrigues, Eduarda Sacardi Severo, Geórgia Camargo Góss, Gabriela Döwich Pradella, Onildo Gonçalves Nunes, Renato Duarte Icart, Marcos da Silva Azevedo

Open full text 3 citations

Abstract

The physical examination has several stages, one of which is the measurement of body temperature, when it exceeds the physiological values is indicative of some disease or hyperthermia, for this in veterinary medicine the mercury or digital thermometer is commonly used. The objective of this work is to compare if there is a difference between the mercury thermometer and the infrared thermometer or digital thermometer, as well as to identify if there is a difference between the measurement locations with the infrared thermometer and the mercury column thermometer and digital thermometer. Infrared temperature was evaluated in three places: oral mucosa, pinna and anal or vaginal mucosa (females), then a digital thermometer, followed by mercury, which was used as a reference standard. There was a statistical difference between the mercury thermometer and the infrared thermometer, when measured on the anal or vaginal mucosa and on the oral mucosa. The infrared thermometer, in the ear, and the digital thermometer did not differ from the mercury thermometer, demonstrating that these present similar values during the temperature measurement. The infrared thermometer proved to be little invasive and fast when compared to the others. However, some limitations were observed in the measurement of body temperature with the infrared thermometer measured in the ear. It is concluded that the infrared thermometer, used in the ear, and the digital thermometer are equivalent to the mercury thermometer and can be used in horses, however, more studies on this topic are still needed.

Open-access reader

About this research paper

What this paper is about

The physical examination has several stages, one of which is the measurement of body temperature, when it exceeds the physiological values is indicative of some disease or hyperthermia, for this in veterinary medicine the mercury or digital thermometer is commonly used. The objective of this work is to compare if there is a difference between the mercury thermometer and the infrared thermometer or digital thermometer, as well as to identify if there is a difference between the measurement locations with the infrared thermometer and the mercury column thermometer and digital thermometer. Infrared temperature was evaluated in three places: oral mucosa, pinna and anal or vaginal mucosa (females), then a digital thermometer, followed by mercury, which was used as a reference standard. There was a statistical difference between the mercury thermometer and the infrared thermometer, when measured on the anal or vaginal mucosa and on the oral mucosa. The infrared thermometer, in the ear, and the digital thermometer did not differ from the mercury thermometer, demonstrating that these present similar values during the temperature measurement. The infrared thermometer proved to be little invasive and fast when compared to the others. However, some limitations were observed in the measurement of body temperature with the infrared thermometer measured in the ear. It is concluded that the infrared thermometer, used in the ear, and the digital thermometer are equivalent to the mercury thermometer and can be used in horses, however, more studies on this topic are still needed.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The physical examination has several stages, one of which is the measurement of body temperature, when it exceeds the physiological values is indicative of some disease or hyperthermia, for this in veterinary medicine the mercury or digital thermometer is commonly used. The objective of this work is to compare if there is a difference between the mercury thermometer and the infrared thermometer or digital thermometer, as well as to identify if there is a difference between the measurement locations with the infrared thermometer and the mercury column thermometer and digital thermometer. Infrared temperature was evaluated in three places: oral mucosa, pinna and anal or vaginal mucosa (females), then a digital thermometer, followed by mercury, which was used as a reference standard. There was a statistical difference between the mercury thermometer and the infrared thermometer, when measured on the anal or vaginal mucosa and on the oral mucosa. The infrared thermometer, in the ear, and the digital thermometer did not differ from the mercury thermometer, demonstrating that these present similar values during the temperature measurement. The infrared thermometer proved to be little invasive and fast when compared to the others. However, some limitations were observed in the measurement of body temperature with the infrared thermometer measured in the ear. It is concluded that the infrared thermometer, used in the ear, and the digital thermometer are equivalent to the mercury thermometer and can be used in horses, however, more studies on this topic are still needed.

Key concepts: Thermometer, Infrared thermometer, Infrared, Mercury (programming language), Temperature measurement, Materials science, Optics, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Gaining body temperature in horses: mercury, digital and infrared thermometer in different locations — Research Paper | ScholarLens