1985CirculationRequires access

Quantitative analysis of the high-frequency components of the signal-averaged QRS complex in patients with acute myocardial infarction: a prospective study.

J AGomes, RMehra, PBarreca, NEl-Sherif, RHariman, RHoltzman

Open publisher page 61 citations

Abstract

We performed a prospective study of the high-frequency components of the terminal portion of the QRS complex in 50 patients with acute myocardial infarction (AMI) (mean age 63 +/- 10 years) within 3.25 +/- 2.45 days of the acute event. Signal averaging (400 beats) at a filter setting of 80 to 300 Hz was performed and the duration of the low-amplitude signals of less than 40 microV in the terminal portion of the QRS, the root-mean-square (RMS) voltage of the terminal 40 msec of the QRS complex, and the total duration of the signal-averaged QRS vector complex were measured. The low-amplitude signals were abnormally prolonged in 22 of 50 patients (44%); the RMS-V was abnormal (less than 20 microV) in 21 of 50 patients (58%), and the signal-averaged vector complex was abnormal (greater than 120 msec) in 15 of 46 patients (33%) without bundle branch block. There was no significant correlation between any of the signal-averaged parameters and site of AMI or total creatine kinase (CK) and CK-MB values. On the ba...

About this research paper

What this paper is about

We performed a prospective study of the high-frequency components of the terminal portion of the QRS complex in 50 patients with acute myocardial infarction (AMI) (mean age 63 +/- 10 years) within 3.25 +/- 2.45 days of the acute event. Signal averaging (400 beats) at a filter setting of 80 to 300 Hz was performed and the duration of the low-amplitude signals of less than 40 microV in the terminal portion of the QRS, the root-mean-square (RMS) voltage of the terminal 40 msec of the QRS complex, and the total duration of the signal-averaged QRS vector complex were measured. The low-amplitude signals were abnormally prolonged in 22 of 50 patients (44%); the RMS-V was abnormal (less than 20 microV) in 21 of 50 patients (58%), and the signal-averaged vector complex was abnormal (greater than 120 msec) in 15 of 46 patients (33%) without bundle branch block. There was no significant correlation between any of the signal-averaged parameters and site of AMI or total creatine kinase (CK) and CK-MB values. On the ba...

Why it matters

OpenAlex reports 61 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We performed a prospective study of the high-frequency components of the terminal portion of the QRS complex in 50 patients with acute myocardial infarction (AMI) (mean age 63 +/- 10 years) within 3.25 +/- 2.45 days of the acute event. Signal averaging (400 beats) at a filter setting of 80 to 300 Hz was performed and the duration of the low-amplitude signals of less than 40 microV in the terminal portion of the QRS, the root-mean-square (RMS) voltage of the terminal 40 msec of the QRS complex, and the total duration of the signal-averaged QRS vector complex were measured. The low-amplitude signals were abnormally prolonged in 22 of 50 patients (44%); the RMS-V was abnormal (less than 20 microV) in 21 of 50 patients (58%), and the signal-averaged vector complex was abnormal (greater than 120 msec) in 15 of 46 patients (33%) without bundle branch block. There was no significant correlation between any of the signal-averaged parameters and site of AMI or total creatine kinase (CK) and CK-MB values. On the ba...

Key concepts: QRS complex, Medicine, Cardiology, Myocardial infarction, Signal averaging, Internal medicine, Bundle branch block, Electrocardiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitative analysis of the high-frequency components of the signal-averaged QRS complex in patients with acute myocardial infarction: a prospective study. — Research Paper | ScholarLens