2021•IEEE Transactions on Industrial ElectronicsRequires access

A Novel Stator Wound Field Flux Switching Machine With the Combination of Overlapping Armature Winding and Asymmetric Stator Poles

Wen Jiang, Wenxin Huang, Xiaogang Lin, Yong Zhao, Xu Dong Wu, Yajun Zhao, Dingfeng Dong, Xuefeng Jiang

Open publisher page 35 citations

Abstract

A novel 24/17-pole 3-phase stator wound field flux switching (SWFFS) machine with the combination of overlapping armature winding (OAW) and asymmetric stator poles (ASP) is proposed for higher torque density in this article. First, the air-gap modulation principle of the 24/17-pole OAW-SWFFS machine is analyzed to better understand its torque production mechanism. Second, since the torque capacity will be greatly restricted by the serious magnetic saturation which is introduced by the OAW configuration, two effective measures are proposed from two perspectives in this article to solve this problem. The first measure is to reduce the magnetic saturation directly by optimizing the area ratio of armature slot and excitation slot, and thus, the torque density can be improved effectively. The second measure is to further enhance the open circuit flux linkages, back electromotive force (EMF), and thus, the torque density by adopting the proposed ASP structure. Furthermore, the accurate ASP distances which are corresponding to the largest back EMF can be obtained effectively based on the air-gap field modulation theory. Finally, the proposed design is validated experimentally by a prototype machine. The simulated and experimental results show that about 25.7% higher torque density can be obtained when compared with 24/14-pole SWFFS machine.

About this research paper

What this paper is about

A novel 24/17-pole 3-phase stator wound field flux switching (SWFFS) machine with the combination of overlapping armature winding (OAW) and asymmetric stator poles (ASP) is proposed for higher torque density in this article. First, the air-gap modulation principle of the 24/17-pole OAW-SWFFS machine is analyzed to better understand its torque production mechanism. Second, since the torque capacity will be greatly restricted by the serious magnetic saturation which is introduced by the OAW configuration, two effective measures are proposed from two perspectives in this article to solve this problem. The first measure is to reduce the magnetic saturation directly by optimizing the area ratio of armature slot and excitation slot, and thus, the torque density can be improved effectively. The second measure is to further enhance the open circuit flux linkages, back electromotive force (EMF), and thus, the torque density by adopting the proposed ASP structure. Furthermore, the accurate ASP distances which are corresponding to the largest back EMF can be obtained effectively based on the air-gap field modulation theory. Finally, the proposed design is validated experimentally by a prototype machine. The simulated and experimental results show that about 25.7% higher torque density can be obtained when compared with 24/14-pole SWFFS machine.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel 24/17-pole 3-phase stator wound field flux switching (SWFFS) machine with the combination of overlapping armature winding (OAW) and asymmetric stator poles (ASP) is proposed for higher torque density in this article. First, the air-gap modulation principle of the 24/17-pole OAW-SWFFS machine is analyzed to better understand its torque production mechanism. Second, since the torque capacity will be greatly restricted by the serious magnetic saturation which is introduced by the OAW configuration, two effective measures are proposed from two perspectives in this article to solve this problem. The first measure is to reduce the magnetic saturation directly by optimizing the area ratio of armature slot and excitation slot, and thus, the torque density can be improved effectively. The second measure is to further enhance the open circuit flux linkages, back electromotive force (EMF), and thus, the torque density by adopting the proposed ASP structure. Furthermore, the accurate ASP distances which are corresponding to the largest back EMF can be obtained effectively based on the air-gap field modulation theory. Finally, the proposed design is validated experimentally by a prototype machine. The simulated and experimental results show that about 25.7% higher torque density can be obtained when compared with 24/14-pole SWFFS machine.

Key concepts: Armature (electrical engineering), Torque density, Stator, Torque, Control theory (sociology), Counter-electromotive force, Direct torque control, Magnet

Related papers

Back to paper searchBrowse research topicsOriginal source
A Novel Stator Wound Field Flux Switching Machine With the Combination of Overlapping Armature Winding and Asymmetric Stator Poles — Research Paper | ScholarLens