2018JRI (Jurnal Radiografer Indonesia)Open access

PERBANDINGAN INFORMASI CITRA ANTARA SEQUENCES T2 FAST FIELD ECHO DAN SUSCEPTIBILITY WEIGHTED IMAGING PADA PEMERIKSAAN MRI BRAIN IRISAN AXIAL DENGAN KASUS MICROBLEEDS

Afandi, Luthfi Rusyadi, Fatimah Fatimah, Jeffry Ardiyanto

Open full text 0 citations

Abstract

Background : The Gradient echo sequence is a sequence using RF excitation pulse varied and with flip NMV through various angle (Instead of 900). It’s sensitive in detecting the present of hemorrhages that have susceptibility and blooming effect to hemorrhages. T2 fast field echo (T2 FFE) and susceptibility weighted imaging (SWI) are part of the gradient echo pulse sequences, in which T2 FFE sequences is conventional non- steady state imaging 2D milti-slice and SWI is 3D velocity compensated sequence gradient echo. On both the sequence is very good for asses the hemorrhages particularly microbleeds. This study aims to determine differences in image information and determine the most optimal image information between T2 FFE and SWI sequences in brain MRI axial slices with microbleeds cases. Methods : Type of research is quantitative experimental approach. The data was taken from October to November 2016 at Radiology Installation of Siloam Hospital Lippo Village. The study populations was all examinations brain MRI with the microbleeds cases, 5 samples with inclusion criteria described. Scanning by using T2 FFE and SWI sequences, then evaluation by respondents furthermore the data was processed using kappa test, and analyzing the date using wilcoxon test, and then to get an assesment of the most optimal images seen from the mean rank wilcoxon test. Results : The result was p-value 0,025 (p<0,05) means that Ho refused and Ha accepted, so that statistically showed significant differences at images information between T2 FFE and SWI sequences in examinations brain MRI axial slices with microbleeds case, with mean rank on SWI sequence is 3, and mean rank on T2 FFE is 0, so it’s can be concluded that SWI sequence produces a better images information on the examination brain MRI axial slices with microbleeds cases than T2 FFE sequence. Conclusion : there is a difference of images information between T2 FFE and SWI sequences in Brain MRI axial slices with microbleeds cases, and SWI sequences produces a better images information on the Brain MRI axial slices with microbleeds cases.

Open-access reader

About this research paper

What this paper is about

Background : The Gradient echo sequence is a sequence using RF excitation pulse varied and with flip NMV through various angle (Instead of 900). It’s sensitive in detecting the present of hemorrhages that have susceptibility and blooming effect to hemorrhages. T2 fast field echo (T2 FFE) and susceptibility weighted imaging (SWI) are part of the gradient echo pulse sequences, in which T2 FFE sequences is conventional non- steady state imaging 2D milti-slice and SWI is 3D velocity compensated sequence gradient echo. On both the sequence is very good for asses the hemorrhages particularly microbleeds. This study aims to determine differences in image information and determine the most optimal image information between T2 FFE and SWI sequences in brain MRI axial slices with microbleeds cases. Methods : Type of research is quantitative experimental approach. The data was taken from October to November 2016 at Radiology Installation of Siloam Hospital Lippo Village. The study populations was all examinations brain MRI with the microbleeds cases, 5 samples with inclusion criteria described. Scanning by using T2 FFE and SWI sequences, then evaluation by respondents furthermore the data was processed using kappa test, and analyzing the date using wilcoxon test, and then to get an assesment of the most optimal images seen from the mean rank wilcoxon test. Results : The result was p-value 0,025 (p<0,05) means that Ho refused and Ha accepted, so that statistically showed significant differences at images information between T2 FFE and SWI sequences in examinations brain MRI axial slices with microbleeds case, with mean rank on SWI sequence is 3, and mean rank on T2 FFE is 0, so it’s can be concluded that SWI sequence produces a better images information on the examination brain MRI axial slices with microbleeds cases than T2 FFE sequence. Conclusion : there is a difference of images information between T2 FFE and SWI sequences in Brain MRI axial slices with microbleeds cases, and SWI sequences produces a better images information on the Brain MRI axial slices with microbleeds cases.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background : The Gradient echo sequence is a sequence using RF excitation pulse varied and with flip NMV through various angle (Instead of 900). It’s sensitive in detecting the present of hemorrhages that have susceptibility and blooming effect to hemorrhages. T2 fast field echo (T2 FFE) and susceptibility weighted imaging (SWI) are part of the gradient echo pulse sequences, in which T2 FFE sequences is conventional non- steady state imaging 2D milti-slice and SWI is 3D velocity compensated sequence gradient echo. On both the sequence is very good for asses the hemorrhages particularly microbleeds. This study aims to determine differences in image information and determine the most optimal image information between T2 FFE and SWI sequences in brain MRI axial slices with microbleeds cases. Methods : Type of research is quantitative experimental approach. The data was taken from October to November 2016 at Radiology Installation of Siloam Hospital Lippo Village. The study populations was all examinations brain MRI with the microbleeds cases, 5 samples with inclusion criteria described. Scanning by using T2 FFE and SWI sequences, then evaluation by respondents furthermore the data was processed using kappa test, and analyzing the date using wilcoxon test, and then to get an assesment of the most optimal images seen from the mean rank wilcoxon test. Results : The result was p-value 0,025 (p<0,05) means that Ho refused and Ha accepted, so that statistically showed significant differences at images information between T2 FFE and SWI sequences in examinations brain MRI axial slices with microbleeds case, with mean rank on SWI sequence is 3, and mean rank on T2 FFE is 0, so it’s can be concluded that SWI sequence produces a better images information on the examination brain MRI axial slices with microbleeds cases than T2 FFE sequence. Conclusion : there is a difference of images information between T2 FFE and SWI sequences in Brain MRI axial slices with microbleeds cases, and SWI sequences produces a better images information on the Brain MRI axial slices with microbleeds cases.

Key concepts: Susceptibility weighted imaging, Gradient echo, Wilcoxon signed-rank test, Flip angle, T2 weighted, Pulse sequence, Fast spin echo, Kappa

Related papers

Back to paper searchBrowse research topicsOriginal source
PERBANDINGAN INFORMASI CITRA ANTARA SEQUENCES T2 FAST FIELD ECHO DAN SUSCEPTIBILITY WEIGHTED IMAGING PADA PEMERIKSAAN MRI BRAIN IRISAN AXIAL DENGAN KASUS MICROBLEEDS — Research Paper | ScholarLens