2021•Clinical CardiologyOpen access

Performance of pulse palpation compared to one‐lead ECG in atrial fibrillation screening

Katrin Kemp Gudmundsdottir, Tove Fredriksson, Emma Svennberg, Faris Al‐Khalili, Leif Friberg, Henrike Häbel, Viveka Frykman, Johan Engdahl

Open full text 10 citations

Abstract

BACKGROUND: The 2020 European Society of Cardiology atrial fibrillation guidelines recommend opportunistic screening for atrial fibrillation by pulse taking or ECG rhythm strip in those aged over 65 years. HYPOTHESIS: We aimed to compare the diagnostic accuracy of pulse palpation to ECG rhythm strip when screening for atrial fibrillation. A secondary aim was to investigate whether participants with palpitations were more likely to be diagnosed with new atrial fibrillation. METHODS: The study population were 75/76 year old individuals that participated in the STROKESTOP II study, a Swedish screening study for atrial fibrillation. Pulse palpation of the radial pulse for 30 sec was performed by healthcare professionals and recorded as regular or irregular. Thereafter a 30-sec single-lead ECG was registered. Patients were asked also if they had a history of palpitations. RESULTS: Of the 6159 participants included in the study, 461 (7.5%) had irregular pulse. Twenty-two (4.8%) of those with irregular pulse were diagnosed with atrial fibrillation on single-lead ECG rhythm strip. Among those with regular pulse, 6 (0.1%) cases of new atrial fibrillation were found. The sensitivity of the pulse palpation test was 78.6% and positive predictive value 4.8%. The proportion of newly diagnosed atrial fibrillation was not different between those with and without history of palpitations. CONCLUSION: Pulse palpation was inferior to single-lead ECG when screening for atrial fibrillation. We therefore advocate the use of single-lead ECG rather than pulse palpation when screening for atrial fibrillation. Palpitations did not predict atrial fibrillation.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: The 2020 European Society of Cardiology atrial fibrillation guidelines recommend opportunistic screening for atrial fibrillation by pulse taking or ECG rhythm strip in those aged over 65 years. HYPOTHESIS: We aimed to compare the diagnostic accuracy of pulse palpation to ECG rhythm strip when screening for atrial fibrillation. A secondary aim was to investigate whether participants with palpitations were more likely to be diagnosed with new atrial fibrillation. METHODS: The study population were 75/76 year old individuals that participated in the STROKESTOP II study, a Swedish screening study for atrial fibrillation. Pulse palpation of the radial pulse for 30 sec was performed by healthcare professionals and recorded as regular or irregular. Thereafter a 30-sec single-lead ECG was registered. Patients were asked also if they had a history of palpitations. RESULTS: Of the 6159 participants included in the study, 461 (7.5%) had irregular pulse. Twenty-two (4.8%) of those with irregular pulse were diagnosed with atrial fibrillation on single-lead ECG rhythm strip. Among those with regular pulse, 6 (0.1%) cases of new atrial fibrillation were found. The sensitivity of the pulse palpation test was 78.6% and positive predictive value 4.8%. The proportion of newly diagnosed atrial fibrillation was not different between those with and without history of palpitations. CONCLUSION: Pulse palpation was inferior to single-lead ECG when screening for atrial fibrillation. We therefore advocate the use of single-lead ECG rather than pulse palpation when screening for atrial fibrillation. Palpitations did not predict atrial fibrillation.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The 2020 European Society of Cardiology atrial fibrillation guidelines recommend opportunistic screening for atrial fibrillation by pulse taking or ECG rhythm strip in those aged over 65 years. HYPOTHESIS: We aimed to compare the diagnostic accuracy of pulse palpation to ECG rhythm strip when screening for atrial fibrillation. A secondary aim was to investigate whether participants with palpitations were more likely to be diagnosed with new atrial fibrillation. METHODS: The study population were 75/76 year old individuals that participated in the STROKESTOP II study, a Swedish screening study for atrial fibrillation. Pulse palpation of the radial pulse for 30 sec was performed by healthcare professionals and recorded as regular or irregular. Thereafter a 30-sec single-lead ECG was registered. Patients were asked also if they had a history of palpitations. RESULTS: Of the 6159 participants included in the study, 461 (7.5%) had irregular pulse. Twenty-two (4.8%) of those with irregular pulse were diagnosed with atrial fibrillation on single-lead ECG rhythm strip. Among those with regular pulse, 6 (0.1%) cases of new atrial fibrillation were found. The sensitivity of the pulse palpation test was 78.6% and positive predictive value 4.8%. The proportion of newly diagnosed atrial fibrillation was not different between those with and without history of palpitations. CONCLUSION: Pulse palpation was inferior to single-lead ECG when screening for atrial fibrillation. We therefore advocate the use of single-lead ECG rather than pulse palpation when screening for atrial fibrillation. Palpitations did not predict atrial fibrillation.

Key concepts: Palpitations, Atrial fibrillation, Medicine, Palpation, Cardiology, Internal medicine, Population, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of pulse palpation compared to one‐lead ECG in atrial fibrillation screening — Research Paper | ScholarLens