2021•IOP Conference Series Materials Science and EngineeringOpen access

Evaluation of action sport camera optical motion capture system for 3D gait analysis

Nardo Rizaldy, F. Ferryanto, A Sugiharto, Andi Isra Mahyuddin

Open full text 5 citations

Abstract

Abstract The high price of motion capture systems on the market has been a hindrance for many hospitals, health agencies and rehabilitation centers to acquire them. Due to its significance in gait analysis, the ITB Biomechanics Research Team has developed affordable motion capture systems since 2008. The advent of Action Sport Cameras (ASC) provide an affordable and portable alternative to the available motion capture systems. Hence, this work investigated the relative accuracy of an ASC based motion capture system. The well-established Vicon V8 with 10 cameras system is utilized in this study to evaluate the proposed ASC Mocap system. Simultaneous gait data acquisition is necessary to ensure valid comparison. Evaluation of the ASC based system was carried out by comparing the spatio-temporal and kinematics parameters obtained with that obtained with Vicon. Based on the parameters obtained, the 4 GoPro Hero 5 cameras system developed by the ITB Biomechanics Team’s is deemed to be suitable to be used in Gait Analysis, especially the spatio-temporal parameters that closely match the Vicon results. For the kinematic parameters, the results obtained while qualitatively similar, in many cases differ in magnitudes. This problem is currently is still under investigation and will be reported in future works.

Open-access reader

About this research paper

What this paper is about

Abstract The high price of motion capture systems on the market has been a hindrance for many hospitals, health agencies and rehabilitation centers to acquire them. Due to its significance in gait analysis, the ITB Biomechanics Research Team has developed affordable motion capture systems since 2008. The advent of Action Sport Cameras (ASC) provide an affordable and portable alternative to the available motion capture systems. Hence, this work investigated the relative accuracy of an ASC based motion capture system. The well-established Vicon V8 with 10 cameras system is utilized in this study to evaluate the proposed ASC Mocap system. Simultaneous gait data acquisition is necessary to ensure valid comparison. Evaluation of the ASC based system was carried out by comparing the spatio-temporal and kinematics parameters obtained with that obtained with Vicon. Based on the parameters obtained, the 4 GoPro Hero 5 cameras system developed by the ITB Biomechanics Team’s is deemed to be suitable to be used in Gait Analysis, especially the spatio-temporal parameters that closely match the Vicon results. For the kinematic parameters, the results obtained while qualitatively similar, in many cases differ in magnitudes. This problem is currently is still under investigation and will be reported in future works.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The high price of motion capture systems on the market has been a hindrance for many hospitals, health agencies and rehabilitation centers to acquire them. Due to its significance in gait analysis, the ITB Biomechanics Research Team has developed affordable motion capture systems since 2008. The advent of Action Sport Cameras (ASC) provide an affordable and portable alternative to the available motion capture systems. Hence, this work investigated the relative accuracy of an ASC based motion capture system. The well-established Vicon V8 with 10 cameras system is utilized in this study to evaluate the proposed ASC Mocap system. Simultaneous gait data acquisition is necessary to ensure valid comparison. Evaluation of the ASC based system was carried out by comparing the spatio-temporal and kinematics parameters obtained with that obtained with Vicon. Based on the parameters obtained, the 4 GoPro Hero 5 cameras system developed by the ITB Biomechanics Team’s is deemed to be suitable to be used in Gait Analysis, especially the spatio-temporal parameters that closely match the Vicon results. For the kinematic parameters, the results obtained while qualitatively similar, in many cases differ in magnitudes. This problem is currently is still under investigation and will be reported in future works.

Key concepts: Motion capture, Kinematics, Motion analysis, Gait, Gait analysis, Computer science, Motion (physics), Sports biomechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of action sport camera optical motion capture system for 3D gait analysis — Research Paper | ScholarLens