2020Radiation Protection DosimetryRequires access

MAPPING OF WORKPLACE RADIATION FIELDS IN DIAGNOSTIC RADIOLOGY FACILITIES USING PERSONNEL MONITORING TLD BADGES

Kshama Srivastava, Shatabdi Chakrabarty, Rajeshri Pai, S M Pradhan, Ajay Chaubey, T. Palani Selvam, B.K. Sapra

Open publisher page 0 citations

Abstract

The radiation protection programme is aimed at safe usage of radiation at workplace, ensuring minimum possible dose to radiation workers, patients and members of the public. Verification of the adequacy of protective measures in actual workplace is important, especially for diagnostic radiology facilities, as a substantial number of suspected overexposures are reported from these facilities. To address this issue, a study was conducted for mapping workplace radiation field at various locations in nine Diagnostic Radiology Facilities of two hospitals in India. The cumulative doses were measured for a period of 1-3 months, using personnel monitoring TLD badges. The dosemeters were placed at positions representative of two exposure situations: (1) probable locations of workers during procedures, leading to genuine exposure and (2) inappropriate storage locations of personal dosemeters at user end for probing claims of nongenuine exposures. The results indicate that the measured doses at locations (1) were just a fraction of the permissible dose, provided all safety practices are adhered to. However, the measured doses at certain locations (2) exceeded the investigation levels and indicate that any inadvertent storage of the dosemeters at such locations could lead to reporting of the overexposure from these radiology facilities. The outcome of the study will be useful for the investigation of such exposures and better understanding of the readout patterns of TLD badges in radiology workplaces.

About this research paper

What this paper is about

The radiation protection programme is aimed at safe usage of radiation at workplace, ensuring minimum possible dose to radiation workers, patients and members of the public. Verification of the adequacy of protective measures in actual workplace is important, especially for diagnostic radiology facilities, as a substantial number of suspected overexposures are reported from these facilities. To address this issue, a study was conducted for mapping workplace radiation field at various locations in nine Diagnostic Radiology Facilities of two hospitals in India. The cumulative doses were measured for a period of 1-3 months, using personnel monitoring TLD badges. The dosemeters were placed at positions representative of two exposure situations: (1) probable locations of workers during procedures, leading to genuine exposure and (2) inappropriate storage locations of personal dosemeters at user end for probing claims of nongenuine exposures. The results indicate that the measured doses at locations (1) were just a fraction of the permissible dose, provided all safety practices are adhered to. However, the measured doses at certain locations (2) exceeded the investigation levels and indicate that any inadvertent storage of the dosemeters at such locations could lead to reporting of the overexposure from these radiology facilities. The outcome of the study will be useful for the investigation of such exposures and better understanding of the readout patterns of TLD badges in radiology workplaces.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The radiation protection programme is aimed at safe usage of radiation at workplace, ensuring minimum possible dose to radiation workers, patients and members of the public. Verification of the adequacy of protective measures in actual workplace is important, especially for diagnostic radiology facilities, as a substantial number of suspected overexposures are reported from these facilities. To address this issue, a study was conducted for mapping workplace radiation field at various locations in nine Diagnostic Radiology Facilities of two hospitals in India. The cumulative doses were measured for a period of 1-3 months, using personnel monitoring TLD badges. The dosemeters were placed at positions representative of two exposure situations: (1) probable locations of workers during procedures, leading to genuine exposure and (2) inappropriate storage locations of personal dosemeters at user end for probing claims of nongenuine exposures. The results indicate that the measured doses at locations (1) were just a fraction of the permissible dose, provided all safety practices are adhered to. However, the measured doses at certain locations (2) exceeded the investigation levels and indicate that any inadvertent storage of the dosemeters at such locations could lead to reporting of the overexposure from these radiology facilities. The outcome of the study will be useful for the investigation of such exposures and better understanding of the readout patterns of TLD badges in radiology workplaces.

Key concepts: Thermoluminescent dosimeter, Medicine, Radiation protection, Medical physics, Radiation exposure, Lead apron, Occupational exposure, Radiation monitoring