저온냉각수 및 Free Cooling 적용에 의한 데이터센터의 냉방성능 검토

Yu-Jin 김유진Kim, Ju-Wan 하주완Ha, Kyung-Soon 박경순Park, Keon-Ho 이건호Lee, Young-Hak 송영학Song

Open publisher page 0 citations

Abstract

The size and number of internet data center (IDC) has been growing rapidly as IT demand has increased recently. IDC needs 10 times as much energy as regular office buildings, there are problems with global warming and increasing carbon emissions. IDC's cooling energy consumption to maintain the IT equipment environment accounts for about 35% of total energy consumption. Therefore, the use of cooling energy was reviewed through simulation by applying the low cooling water temperature system and the free cooling system in this system. Based on this, cooling performance was analyzed using MLC (Mechanical Load Component) indicators. As a result of the simulation, energy consumption in low cooling water temperatures decreased by 8% compared to normal water-cooling systems, while WSE (Water Side Economizer) and ASE (Air Side Economizer) decreased by 26% and 32%, respectively. Since the MLC of conventional water-cooled system was 0.13 which is lower than Incheon's maximum allowable value of 0.18. As a result of the MLC analysis, it was determined that the cooling system was properly designed. The cooling energy usage showed a significant reduction rate in the order of low cooling water temperature, WSE, and ASE, and the ASE was the most efficient operation with 26.3%.

About this research paper

What this paper is about

The size and number of internet data center (IDC) has been growing rapidly as IT demand has increased recently. IDC needs 10 times as much energy as regular office buildings, there are problems with global warming and increasing carbon emissions. IDC's cooling energy consumption to maintain the IT equipment environment accounts for about 35% of total energy consumption. Therefore, the use of cooling energy was reviewed through simulation by applying the low cooling water temperature system and the free cooling system in this system. Based on this, cooling performance was analyzed using MLC (Mechanical Load Component) indicators. As a result of the simulation, energy consumption in low cooling water temperatures decreased by 8% compared to normal water-cooling systems, while WSE (Water Side Economizer) and ASE (Air Side Economizer) decreased by 26% and 32%, respectively. Since the MLC of conventional water-cooled system was 0.13 which is lower than Incheon's maximum allowable value of 0.18. As a result of the MLC analysis, it was determined that the cooling system was properly designed. The cooling energy usage showed a significant reduction rate in the order of low cooling water temperature, WSE, and ASE, and the ASE was the most efficient operation with 26.3%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The size and number of internet data center (IDC) has been growing rapidly as IT demand has increased recently. IDC needs 10 times as much energy as regular office buildings, there are problems with global warming and increasing carbon emissions. IDC's cooling energy consumption to maintain the IT equipment environment accounts for about 35% of total energy consumption. Therefore, the use of cooling energy was reviewed through simulation by applying the low cooling water temperature system and the free cooling system in this system. Based on this, cooling performance was analyzed using MLC (Mechanical Load Component) indicators. As a result of the simulation, energy consumption in low cooling water temperatures decreased by 8% compared to normal water-cooling systems, while WSE (Water Side Economizer) and ASE (Air Side Economizer) decreased by 26% and 32%, respectively. Since the MLC of conventional water-cooled system was 0.13 which is lower than Incheon's maximum allowable value of 0.18. As a result of the MLC analysis, it was determined that the cooling system was properly designed. The cooling energy usage showed a significant reduction rate in the order of low cooling water temperature, WSE, and ASE, and the ASE was the most efficient operation with 26.3%.

Key concepts: Free cooling, Economizer, Water cooling, Energy consumption, Environmental science, Active cooling, Cooling load, Air cooling