2020Current Trends in Biotechnology and PharmacyRequires access

Development and Validation of Stability Indicating RP-HPLC Method for Quantitative Estimation of Levofloxacin Injection 5mg/ml Dosage Form

N. Prasad Babu, Ramachandran D Ramachandran, K. Bhavani

Open publisher page 4 citations

Abstract

A new analytical “reverse phase high performance liquid Chromatography (RP-HPLC) assay method has been developed for estimation of” Levofloxacin in injection phase. The separation was achieved by using column Inertsil ODS-3V (250 x 4.6mm, 5μm) mobile phase consisted of 0.05 M solution of citric acid monohydrate and 10 ml of 1.0 M ammonium acetate buffer and acetonitrile in the ratio of (85:15 v/v) . The flow rate was 1.0mL.min-1. Levofloxacin was detected using UV detector at the wavelength of 293 nm. The retention time of Levofloxacin was noted to be 11.20 min respectively. The method was evaluated as per ICH guidelines. The proposed method was found to be advantageous than the existing methods towards accuracy, reproducibility, and consistent.

About this research paper

What this paper is about

A new analytical “reverse phase high performance liquid Chromatography (RP-HPLC) assay method has been developed for estimation of” Levofloxacin in injection phase. The separation was achieved by using column Inertsil ODS-3V (250 x 4.6mm, 5μm) mobile phase consisted of 0.05 M solution of citric acid monohydrate and 10 ml of 1.0 M ammonium acetate buffer and acetonitrile in the ratio of (85:15 v/v) . The flow rate was 1.0mL.min-1. Levofloxacin was detected using UV detector at the wavelength of 293 nm. The retention time of Levofloxacin was noted to be 11.20 min respectively. The method was evaluated as per ICH guidelines. The proposed method was found to be advantageous than the existing methods towards accuracy, reproducibility, and consistent.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new analytical “reverse phase high performance liquid Chromatography (RP-HPLC) assay method has been developed for estimation of” Levofloxacin in injection phase. The separation was achieved by using column Inertsil ODS-3V (250 x 4.6mm, 5μm) mobile phase consisted of 0.05 M solution of citric acid monohydrate and 10 ml of 1.0 M ammonium acetate buffer and acetonitrile in the ratio of (85:15 v/v) . The flow rate was 1.0mL.min-1. Levofloxacin was detected using UV detector at the wavelength of 293 nm. The retention time of Levofloxacin was noted to be 11.20 min respectively. The method was evaluated as per ICH guidelines. The proposed method was found to be advantageous than the existing methods towards accuracy, reproducibility, and consistent.

Key concepts: Chromatography, Levofloxacin, High-performance liquid chromatography, Reproducibility, Ammonium acetate, Citric acid, Acetonitrile, Retention time

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and Validation of Stability Indicating RP-HPLC Method for Quantitative Estimation of Levofloxacin Injection 5mg/ml Dosage Form — Research Paper | ScholarLens